AR3 confirms near surface Uranium discovery at Overland
Released
Released
Announcement PDF
19 March 2025
AR3 confirms near surface Uranium
discovery at Overland
Highlights:
•
Discovery of widespread calcrete hosted Uranium: Follow-up drilling of hole
OV047’s shallow anomalous gamma and pXRF (U) readings (See ASX 6 March 2025)
has confirmed a widespread continuation of calcrete hosted uranium
mineralisation.
•
Extensive target area: The modern drainage setting indicates significant
mineralisation potential at Overland, with drilling revealing an anomalous
mineralised zone up to 6m thick and over 1km wide remaining open in all directions.
•
Confirmation of an additional Uranium model: Mineralogical assessments of drill
cuttings from Hole OV047 confirm a calcrete-hosted style of mineralisation, with
uranium present in the secondary calcite cementation of both limestone and sandy
sediments.
•
Dual Uranium potential at Overland: Overland now demonstrates potential for
both near surface, calcrete-hosted uranium and deeper, ISR-amenable deposits,
emphasising the value of the company's vast 4,000km² exploration land package in
a frontier uranium play.
•
Next steps: AR3 will undertake follow up drilling on this new surficial uranium
discovery, continue to test high-priority targets for deeper ISR-amenable deposits,
and explore new leads identified within the vast Overland project area. Assay results
from recent drilling are expected to be released progressively over the next few
months.
•
Engage with this announcement at the AR3 investor hub.
AR3 Managing Director and CEO, Travis Beinke, said:
"AR3’s exploration team has delivered exceptional results with its 2025 drilling program.
Confirming calcrete-hosted uranium, along with the previously identified ISR potential,
significantly enhances the strategic value of our 4,000 km² land holding. This discovery
validates our exploration approach and demonstrates the latent potential of the Overland
project. We're just scratching the surface of what's possible. We'll continue drilling
through April and keep the market informed of our progress."
Figure 1: Section A- A’ displaying lithology interpretation, natural gamma responses (cps) and pXRF uranium responses (ppm
U). In relation to the disclosure of pXRF results, the Company cautions that estimates of uranium elemental abundance
from pXRF results should not be considered a proxy for quantitative analysis of a laboratory assay result. Assay results are
required to determine the actual widths and grade of the mineralisation. The company uses an Olympus Vanta M Series
portable X-ray Fluorescence (pXRF) analyzer to screen Air Core drilling samples for mineralization prior to submitting samples
to a commercial laboratory for assay. This provides an initial understanding of the mineralization distribution before sampling,
ensuring submitted samples are representative of the targeted mineralization. While pXRF confirms the presence of
mineralization, it does not accurately determine elemental concentrations due to limitations such as a small analysis window,
uneven distribution, shallow penetration depth, and irregular surfaces. The pXRF results are indicative and the pXRF readings
are subject to confirmation by chemical analysis from an independent laboratory.
Figure 2: Section B-B’ displaying lithology interpretation, natural gamma responses (cps) and pXRF uranium responses (ppm
U).
Australian Rare Earths Limited (ASX: AR3) is pleased to announce encouraging results from its
ongoing exploration drilling program at the Overland Uranium Project.
Follow-up drilling of hole OV047’s anomalous gamma and pXRF (U) readings in shallow
carbonate-cemented sediments (See ASX 6 March 2025) has confirmed a widespread
continuation of calcrete hosted uranium mineralisation.
Nine drillholes targeting the shallow carbonate-cemented sediments have all confirmed
anomalous gamma and pXRF (U) responses. The discovery of calcrete-hosted uranium
mineralisation at Overland remains open in all directions, with an extensive setting spanning
dozens of kilometers of strike length along the modern drainage profile and across its >1km width.
The additional modern drainage profile outlined as Target 2 (see Figure 3) suggests further
potential for this style of mineralisation at Overland.
The discovery drilling was conducted at 100m to 600m spacings to depths of up to 42m, with
anomalous zones occurring between 20m and 32m depth - detailed in sections in Figures 1 and
2.
Initial indications of a shallow uranium occurrence at Target 1 of EL6678 came in drillhole OV047,
which intersected a 6-meter interval containing anomalous gamma and pXRF Uranium (U)
responses. Gamma responses peaked at 741 counts per second (cps), with maximum pXRF
uranium response of 105ppm U in that hole. Subsequent drilling has provided further evidence of
this style of mineralisation, with gamma responses peaking at 1,010cps in hole OV050 and
additional anomalous pXRF uranium (U) values exceeding 50ppm occurring in holes OV050 and
OV053. The identified anomalous zones range from 2m to 6m in thickness.
Mineralogical assessments of Hole OV047 drill cuttings through scanning electron microscope
(SEM) and micro XRF analysis indicate that uranium is hosted in the secondary calcite
cementation of both the limestone and the sandy sediments in this setting. Indicative uranium
levels of up to ~350ppm U have been detected in the calcite cement infilling these sediments.
The uranium within the calcite cement was identified by analysing samples with a Bruker M4
Tornado Plus µXRF instrument operated by Adelaide Microscopy at the University of Adelaide 1.
This shallow sedimentary uranium mineralisation in secondary carbonate cementation is similar
to Namibia’s surficial uranium deposits, as found at Paladin Energy’s Langer Heinrich mine or
Deep Yellow’s Tumas project. Similar calcrete-hosted deposits are also found in Western
Australia at Cameco Corporation’s Yeelirrie deposit and Toro Energy’s Wiluna project.
This instrument behaves much like the handheld pXRF, however the incident X-Ray beam is focussed to
~15µm in diameter, allowing for targeted spot analysis and x-ray “imaging” by moving the sample under
the focussed x-ray beam. In relation to the disclosure of µXRF results, the Company cautions that
estimates of uranium elemental abundance from µXRF results should not be considered a proxy for
quantitative analysis of a laboratory assay result. Assay results are required to determine the actual
widths and grade of the mineralisation.
1
Figure 3: Overland drilling (2024 & 2025) with airborne radiometrics, alluvial sediment channels, and interpreted
palaeochannel boundary based on recent drilling. Target 1 follow up drilling shown in inset Figure. Note: The airborne
radiometric image and Alluvial Sediment Outline is publicly available data sourced from SARIG ( https://map.sarig.sa.gov.au)
and detailed within the appendices of this report.
Figure 4: Inset Figure, section location plan.
Next steps
AR3’s initial 2025 drilling program will continue to follow up the shallow uranium occurrence
intersected in the Target 1 area to determine its extent, and to test Target 2 for similar
mineralisation style. In addition, initial high priority targets on EL6678 will be drill tested targeting
deeper palaeochannel hosted, in-situ recoverable (ISR) deposits.
Drilling will also target the highly prospective drill targets along the western margin of a
palaeovalley setting within EL7001 defined through drilling completed in 2024 and more recently
in 2025 (Figure 3).
AR3 has sent samples from the recent drilling for assay analysis and expects results to be
released progressively over the next few months.
The announcement has been authorised for release by the Board of Australian Rare Earths Limited.
For further information please contact:
Australian Rare Earths Limited
Travis Beinke
Managing Director and CEO
T: 1 300 646 100
Media Enquiries
Jessica Fertig
Tau Media
E: info@taumedia.com.au
Engage and Contribute at the AR3 investor hub: https://investorhub.ar3.com.au/
Competent Person’s Statement
The information in this report that relates to Exploration results is based on information compiled by Australian
Rare Earths Limited and reviewed by Mr Rick Pobjoy who is the Chief Technical Officer of the Company and a
member of the Australian Institute of Mining and Metallurgy (AusIMM). Mr Pobjoy has sufficient experience that
is relevant to the style of mineralisation, the type of deposit under consideration and to the activities undertaken
to qualify as a Competent person as defined in the 2012 edition of the “Australasian Code for Reporting of
Exploration Results, Mineral Resources and Ore Reserves”. Mr Pobjoy consents to the inclusion in this report of
the matters based on this information in the form and context in which it appears.
About Australian Rare Earths Limited
Australian Rare Earths is committed to the timely exploration and development of its 100% owned, flagship
Koppamurra Project, located in the new Koppamurra rare earths Province in southeastern South Australia and
western Victoria. Koppamurra is a prospective ionic clay hosted rare earth deposit, rich in all the elements
required in the manufacture of rare earth permanent magnets which are essential components in electric
vehicles, wind turbines and domestic appliances. In addition, AR3 is actively reviewing other potential
prospective areas which may also host uranium and ionic clay hosted rare earth deposits throughout Australia.
The Company is focused on executing a growth strategy that aims to position AR3 as an independent and
sustainable source of energy transition metals, playing a pivotal role in the global transition to a green economy.
JORC Table 1
Criteria
Sampling
techniques
Section 1 Sampling Techniques and Data
Explanation
Comment
Nature and quality of
Air Core drilling methods were used to obtain
samples from the Overland drilling program
sampling (e.g., cut
channels, random chips, or between October-December 2024 and JanuaryMarch 2025
specific specialised
industry standard
The following information details the Air Core drill
measurement tools
sampling process:
appropriate to the
minerals under
• All Air Core drill samples were collected from
investigation, such as
the rotary splitter mounted at the bottom of
down hole gamma sondes,
the cyclone into a pre‐numbered calico bag.
or handheld XRF
The samples were geologically logged at 1 m
instruments, etc). These
intervals.
examples should not be
taken as limiting the broad • Based on hole‐diameter, generic material
density and a 20% split on the cyclone
meaning of sampling.
samples averaged ~1.5‐2.5 kg in mass.
Include reference to
measures taken to
• Chip trays were used to collect a
ensure sample
representative sample for each 1m sample
representivity and the
interval for each hole.
appropriate calibration
• After the samples were collected within the
of any measurement
calico bags, they were screened for
tools or systems used.
anomalous gamma radiation using a
Aspects of the
handheld Ranger EXP survey meter (S/N
determination of
R318772) calibrated 23/09/2024 prior to
mineralisation that are
being geologically logged and tested with a
Material to the Public
pXRF at the drill site.
Report. In cases where
‘industry standard’ work
•
has been done this would
be relatively simple (e.g.,
‘reverse circulation drilling
was used to obtain 1 m
samples from which 3 kg
was pulverised to produce a
30 g charge for fire assay’).
In other cases, more
•
explanation may be
required, such as where
there is coarse gold that has
inherent sampling problems.
Unusual commodities or
mineralisation types (e.g.,
submarine nodules) may
warrant disclosure
•
of detailed information
The gamma screening was conducted by
placing the handheld Ranger survey meter
~10cm from the calico sample for 5‐10sec and
noting the dose rate in µSv. If elevated dose
rates were detected the field crew was then
notified before any additional sample logging
was conducted and the anomalous reading
recorded in the geological log.
A handheld Olympus Vanta pXFR Analyser
(Model Vanta M Series S/N 842924) was used
to assess the geochemistry of the Air Core
samples in the field. The pXRF analysis
provided screening analysis to characterize
the sample lithology and full suite of
elements.
The pXRF sampling was analyzed through
the calico bag with a beam count time of 2030 sec beam 1 and 10 sec beam 2. One pXRF
analysis per sample was performed.
.
•
Samples are laid on a workbench and
flattened to create a stable surface for the
pXRF. The pXRF is placed on the sample with
the beam down for the analysis.
•
All readings were taken at ambient
temperatures between 10 and 45 degrees
Celsius. The Olympus Vanta is rated
for continuous
operation
within
these temperatures.
•
Samples range from dry to wet, this is
dependent on which formation is
being intercepted and whether drilling
water has been injected.
•
A Uranium standard Oreas 121 (215 ppm U,
sourced from Mantra Resources
Nyota Prospect, Tanzania, which is a
Tabular Sandstone hosted deposit) was
used to verify the accuracy of the pXRF
before and after each analysis session.
•
The OREAS 121 standard was prepared using
an industry standard pXRF sample cup and
analyzed for 20-30 sec on beam 1 and 10 Sec
on beam 2.
•
A silica blank is used to monitor the
accumulation of contamination on the lens
of the pXRF. Analysis of the blank
is undertaken before and after each analysis
session.
•
Review of pXRF standard and blank data is
checked to ensure the pXRF is operating
correctly before and after each session.
•
After the hole was drilled to completion a
Reflex EZ Gamma logging tool (serial number
GAM‐043) rented from Imdex, and operated
by the drilling crew was run down the hole,
inside the rods/innertube to log the natural
gamma response of the sediments. The
gamma tool was last calibrated by Imdex on
October 9th 2024 as noted in the provided
Certificate of Conformance.
•
The survey was run in and out of the hole at a
speed of no more than 10m/min and the
downhole speed was reviewed after the
survey.
•
The up (out) survey was then used to plot
sections, after reviewing both in and out
surveys
• Before each downhole gamma survey the
Reflex EZ Gamma logging tool was checked
with an EZ‐Gamma confidence checker by
AR3 staff (S/N 025). The confidence checker
was last calibrated 29/08/24.
• Using the EZ‐Gamma confidence checker at
the start of each run allows the gamma tool
to be checked ensuring it is within
specifications and the tool has not been
damaged or faulty providing confidence an
accurate gamma reading is collected for
each hole.
• The check is completed by first running the
gamma tool for ~3-5min to measure
Background Gamma (BKG) in cps. A second
survey is then conducted after sliding the EZ‐
Gamma Confidence checker over the gamma
probe and measuring a Sleeve Response (SR)
in cps. The BKG value is subtracted from the
SR value which provides a Calculated Sleeve
Response (CSR) value in cps. The CSR is then
compared to the Expected Value (EV) which
is certified to be 600 cps. A resulting pass
value 600 cps +/‐ 10 % is required before the
survey tool is confirmed as operating within
expected limits.
• The formula used for checking the gamma
tool is as follows;
• CSR-EV = 600 +/- 10% (or a pass value of 540660cps) where CSR= SR-BKG
• After the gamma survey is completed, the
data is uploaded to the Imdex hub IQ portal
(https://iq.imdexhub.com) from the rig via
satellite internet and available for review.
Drilling
techniques
Drill type (e.g., core,
•
reverse circulation, open‐
hole hammer, rotary air
blast, auger, Bangka,
•
sonic, etc) and details
(e.g., core diameter, triple
or standard tube, depth of
diamond tails, face‐
sampling bit, or other type,
whether core is oriented and
if so, by what method, etc). •
•
Drilling was completed using a Wallis “Mantis
200” Air Core drill rig with an onboard Sullair
compressor (560cfm @ 200psi).
Aircore drilling is a form of reverse circulation
drilling where the sample is collected at
the face and returned inside the inner tube.
The drill cuttings are removed by injection of
compressed air into the hole via the annular
area between the inner tube and the drill rod.
Aircore drill rods used were 3 m long.
NQ diameter (76 mm) drill bits and rods were
used.
Drill sample
recovery
Method of recording and
assessing core and chip
sample recoveries and
results assessed.
Measures taken to
maximise sample recovery
and ensure representative
nature of the samples.
Whether a relationship
exists between sample
recovery and grade and
whether sample bias may
have occurred due to
preferential loss/gain of
fine/coarse material.
•
All aircore drill holes were vertical with depths
varying between ~33 m and 200 m.
•
Drill sample recovery for Air Core drilling is
monitored by recording sample condition
descriptions where ‘Poor’ to ‘Very Poor’ were
used to identify any samples recovered which
were potentially not representative of the
interval drilled.
A comment was included where water
injection was required to recover the sample
from a particular interval. The use of water
injection can potentially bias a sample.
Minimal water injection was required during
this drilling program and used sparingly.
Overall, no consistent/significant losses of
sample material was observed.
The rotary splitter was set to an approximate
20% split, which produced approximately
1.5‐2.5 kg sample for each meter interval.
The 1.5‐2.5 kg sample was collected in a pre‐
numbered calico bag and the remaining 80%
(5 kg to 8 kg) was disposed directly into the
sump as drilling progressed.
At the end of each drill rod, the drill string is
cleaned by blowing down with air to remove
any clay and silt potentially built up in the
sample pipes and cyclone.
The relationship (if any) between sample
recovery and grade is unknown
No sample recovery information was reported
in historical reports relating to
historical drilling within this release.
•
•
•
•
•
•
•
Logging
Whether core and chip
samples have been
geologically and
geotechnically logged to a
level of detail to support
•
All Air Core samples collected in calico bags
were logged for lithology, color, cement type,
hardness, percentage rock estimate, and any
relevant comments such as moisture, sample
condition, evidence of
appropriate Mineral
Resource estimation,
mining studies and
•
metallurgical studies.
Whether logging is
qualitative or quantitative
in nature. Core (or
costean, channel, etc)
photography.
The total length and
•
percentage of the relevant
intersections logged.
•
Sub‐sampling
techniques
and sample
preparation
If core, whether cut or
sawn and whether
quarter, half or all cores
taken.
If non‐core, whether
riffled, tube sampled,
rotary split, etc and
whether sampled wet or
dry.
For all sample types, the
nature, quality, and
appropriateness of the
sample preparation
technique.
Quality control
procedures adopted for
all sub‐sampling stages to
maximise representivity
of samples.
Measures taken to ensure
that the sampling is
representative of the in‐
situ material collected,
including for instance
results for field
duplicate/second‐half
sampling.
reducing or oxidizing conditions, and
vegetation/organic material.
Geological logging data for all drill holes was
qualitatively logged onto Microsoft Excel
spreadsheet using a field laptop with validation
rules built into the spreadsheet including
specific drop‐ down menus for each variable.
The data was uploaded to the Australian Rare
Earths Azure Data Studio database.
Every drill hole was logged in full and logging
was undertaken with reference to a drilling
template with codes prescribed and guidance
to ensure consistent and systematic data
collection.
The density of drilling is not sufficient to
support consideration of resource estimation,
or mining and no geotechnical logging was
completed.
• 1m Air Core sample interval was
homogenized within the cyclone and the
rotary splitter was set to an approximate
20% split producing around 1.5‐2.5 kg
sample for each meter interval.
• The 1.5‐2.5kg sample was collected in a pre‐
numbered calico bag.
• Duplicates were generally taken within
intervals which indicated potential for
anomalous U mineralization based on
geology, pXRF, and gamma signature. These
duplicate samples were collected by splitting
the 1m interval by emptying the sample on
to a table, mixing and splitting into 1/8th
subsamples and randomly assigning 4 of the
splits into the duplicate and 4 remaining as
the primary.
• The 1.5‐2.5 kg sample collected in the calico
bag was logged by the geologist onsite.
• Approximately 10‐20g of sample material
from each for each 1m calico sample placed
in a chip tray.
• The logged calico samples were scanned
with a pXRF onsite through the calico bag.
• At the end of the drillhole samples were
selected for analysis.
Whether sample sizes are
appropriate to the grain
size of the material being
sampled.
• Samples selected for analysis were placed in
polyweave bags labelled with the sample
number, From‐To interval, and Hole ID, then
segregated into bulka bags for transport to
the lab for analysis.
• No correction factors were applied to pXRF
results.
• Field duplicates of all the samples were
completed at a frequency of ~1 in 40
samples. Field standards were inserted into
the sample sequence at a frequency of
~1:40. Standard reference Material (SRM)
samples were inserted into the sample
batches at a frequency rate of 1 per 10
samples by the laboratory and a repeat
sample was taken at a rate of 1 per 21
samples.
• An on‐site geologist oversaw the sampling
and logging process and selected samples for
analysis based on the logging descriptions
p X R F analysis, and downhole gamma
response.
Quality of
assay data
and
laboratory
tests
The nature, quality and
appropriateness of the
assaying and laboratory
procedures used and
whether the technique is
considered partial or total.
For geophysical tools,
spectrometers, handheld
XRF instruments, etc, the
parameters used in
determining the analysis
including instrument make
and model, reading times,
calibrations factors
applied and their
derivation, etc.
Nature of quality control
procedures adopted (e.g.,
standards, blanks,
duplicates, external
laboratory checks) and
whether acceptable levels
of accuracy (i.e., lack of
bias) and precision have
been established.
•
•
•
•
Scanning Electron Microscope (SEM) and
µXRF Analysis referred to in this report was
completed by Adelaide Microscopy by Dr.
Ben Wade, Electron Microscopist specializing
in Geological techniques, ICPMS, SEM,
Electron Microprobe, X-Ray Analysis and
Physical Science Preparations. Dr. Ben Wade
is also the State Representative for AMAS.
Two samples were selected for SEM and µXRF
analysis from Hole OV047. One sample from
28m (sample # 28/1) and a second sample
from 30m (sample # 30/1).
The analysis was largely to determine if
Uranium was hosted in discrete U rich phases
in the limestone, or if hosted as low-level
Uranium in the carbonate cement itself.
The two chip samples were mounted in
Struers Epofix resin and cured overnight.
Following this, a flat surface was prepared
on progressively finer wet and dry sandpaper
under kerosene (400/800/1000 grit). After
this step, samples were hand polished under
kerosene with 9µm, 3µm and 1µm oil based
diamond paste, then washed thoroughly and
ultrasonically bathed under 100% ethanol.
Sample # 30/1 of carbonate cemented
sandstone was friable and difficult to polish,
and many sand grains plucked out during the
polishing step. However enough remained of
the sample that was polished to conduct
analysis on. Following this samples were
carbon coated (~15nm thick layer) ready for
SEM analysis.
•
SEM observation was conducted on a Hitachi
SU3800 microscope using backscattered
electron imaging (BSE), and x-ray analyses
were conducted with a Bruker EDS detector.
On a flat polished surface, variations in
greyscale under BSE are directly related to
compositional differences, in which
“brighter” phases contain more “heavy
elements” such as Uranium in this case. As
such, particular interest was paid to “bright”
particles on the BSE images to determine if
any of them were U bearing. In both samples
28/1 and 30/1 no U bearing phases were
found, with most bright particles being either
iron oxides, baryte, or monazite (1 grain with
no detectable U in it). No detectable U peak
was seen in calcite analyses on the SEM,
which was to be expected as the typical
elemental detection limit of SEM-EDS
analysis is around ~2-3000ppm
•
Following the SEM imaging and analysis,
samples were then put into a Bruker M4
Tornado Plus µXRF instrument. This
instrument behaves much like the handheld
pXRF, however the incident X-Ray beam is
focussed to ~15µm in diameter, allowing for
targeted spot analysis and x-ray “imaging”
by moving the sample under the focussed xray beam. As such both chips were first
imaged at a coarse pixel resolution of 100µm
to get a broad view of the spatially resolved
chemistry, then after this targeted single
point analysis was done on select locations
on both samples to detect low level Uranium.
All targeted is done from the 10x optical
image on the microscope, and as such spot
analysis on sample # 30/1 targeting only the
carbonate cement was difficult due to the
fine grained nature of it and lack of optical
contrast in minerals. As a result most
analytical spectra on sample # 30/1 hit the
quartz grains which are the bulk of the
sample.
•
µXRF Spot analysis was completed on two
areas (Area1 and Area2) on sample # 28/1
and one area (Area1) on sample # 30/1, with
8 spot analysis done on each area.
Verification
of sampling
and assaying
The verification of
significant intersections by
either independent or
alternative company
personnel.
The use of twinned holes.
Documentation of primary
data, data entry
procedures, data
verification, data storage
(physical and electronic)
protocols.
Discuss any adjustment to
assay data.
Location of
data points
Accuracy and quality of
surveys used to locate drill
holes (collar and down‐
hole surveys), trenches,
mine workings and other
locations used in Mineral
Resource estimation.
Specification of the grid
system used.
Quality and adequacy of
•
A total of 4 spot analysis from Area 1 sample
28/1 reported anomalous U within a calcite
cement ranging between (0.024-0.036
elemental wt% U) and 1 spot analysis from
Area 1 sample 30/1 reported anomalous U
within a carbonate cement (0.015 elemental
wt% U).
•
No other anomalous U was detected in the
spot analysis.
• All results are checked by the company’s
Chief Technical Officer.
• Field based geological logging for drill holes
was entered directly into an Excel spreadsheet
format with validation rules built into the
spreadsheet including specific drop‐down menus
for each variable. This digital data was then
uploaded to the Australian Rare Earths Azure Data
Studio database.
• Assay data will be received in digital format
from the laboratory and uploaded to Australian
Rare Earths Azure Data Studio database.
• Field and laboratory duplicate data pairs of
each batch will be plotted to identify potential
quality control issues.
• Standard Reference Material sample results
will be checked from each sample batch to ensure
they are within tolerance (<3SD) and that there is
no bias.
• U3O8 is the industry accepted form for reporting
Uranium. An oxide factor for U3O8 of 1.1793
was used for reporting throughout this report.
• All maps are in GDA94/MGA zone 54.
• All overland coordinate information was
collected using handheld GPS utilizing
GDA 1994, Zone 54. While spatial
location is expected to be recovered
within 3 – 5 m, it is possible that the
elevation can be as much as 10 m out
with respect to the currently established
geoid.
topographic control.
Data spacing
and
distribution
Orientation
of data in
relation to
geological
structure
Data spacing for reporting
of Exploration Results.
Whether the data spacing,
and distribution is
sufficient to establish the
degree of geological and
grade continuity
appropriate for the
Mineral Resource and Ore
Reserve estimation
procedure(s) and
classifications applied.
Whether sample
compositing has been
applied.
Whether the orientation of
sampling achieves
unbiased sampling of
possible structures and the
extent to which this is
known, considering the
deposit type.
If the relationship between
the drilling orientation and
the orientation of key
mineralised structures is
considered to have
introduced a sampling
bias, this should be
assessed and reported if
material.
• Drillhole RL has been corrected using An
Australian wide SRTM. The 1 second
SRTM Level 2 Derived Smoothed Digital
Elevation Model (DEM‐S) is derived from
the 2000 SRTM. The DEM‐S has a ~30m
grid which has been adaptively
smoothed to improve the representation
of the surface shape and is the preferred
method for shape and vertical accuracy
from STRM products. The smoothing
process estimated typical improvements
in the order of 2‐3 m. This would make
the DEM‐S accuracy to be of
approximately 5 m.
• Locations of Overland drill holes are
reported within the appendices of this
report.
•
No geological or grade continuity estimations
are being determined from the Overland
drilling data.
•
All Overland drill holes were drilled
vertically as detailed in the appendices of
this report.
•
There is no indication that a sampling
bias exists as the geology is relatively flat
lying therefore vertical holes are
appropriate.
Sample
security
The measures taken to
ensure sample security.
•
•
Audits or
reviews
The results of any audits
or reviews of sampling
techniques and data.
After logging, the samples in calico bags
were tied and placed into polyweave bags,
labelled with the drill hole and sample
numbers contained within the polyweave
and transported to the site laydown area,
at the end of each day.
Sample selections w
Share your feedback
Discover