Extension of Uranium mineralisation at Overland
Released
Released
Announcement PDF
28 March 2025
Extension of Uranium mineralisation at
Overland’s Western Margin Target
Highlights:
•
Uranium mineralisation extended: Remainder of assays from 2024 drilling
confirms uranium mineralisation along the highly prospective Western Margin Target
Zone.
•
Validation of depositional model: Correlation of assay results with gamma and
pXRF data confirms the depositional model for sedimentary-hosted uranium.
•
Anomalous Uranium: Drill holes OV012 and OV013 intersected anomalous
uranium concentrations over 1m intervals at key geological contacts between
permeable sands and lignitic clays.
•
Assays validate the down hole gamma responses and in-field pXRF
measurements for contained Uranium including:
o OV012
1m at 51ppm U3O8 from 89m (Figure 2 & 5)
o OV012
1m at 43ppm U3O8 from 102m
o OV013
1m at 61ppm U3O8 from 85m (Figure 2 & 5)
o OV013
1m at 39ppm U3O8 from 84m
o OV015
1m at 36ppm U3O8 from 61m
o OV023
1m at 32ppm U3O8 from 79m
o OV025
1m at 31ppm U3O8 from 85m
o OV011
1m at 30ppm U3O8 from 96m
•
ISR amenable mineralisation: Uranium mineralisation occurs in permeable
sediments conducive to In-Situ Recovery (ISR) mining methods.
•
Active Uranium system supported: Results suggest an active system, increasing
potential for future discoveries at the Overland Project.
•
Next round assays pending: Assays from the first swing of the 2025 drilling program
are expected in the coming weeks, which will guide future exploration targeting.
•
Engage with this announcement at the AR3 investor hub.
AR3 Managing Director and CEO, Travis Beinke, said:
“We're pleased to announce the extension of uranium mineralisation along the highly prospective
Western Margin Target Zone at our Overland Project. These assay results validate our geological
model for ISR amendable uranium mineralisation. To confirm there is a working system with
uranium present so early in our exploration efforts is a great start and reinforces our confidence
in the project's potential.
This milestone is another step forward as we continue to advance Overland towards becoming a
key asset in our portfolio. The upcoming assay results from the first swing of our 2025 drilling
program will further guide our strategic exploration plans. We remain committed to unlocking the
full potential of the Overland Project, including prioritising follow up drilling of the recent
discovery of shallow calcrete hosted uranium and delivering long-term value to our shareholders."
Australian Rare Earths Limited (ASX: AR3) is pleased to provide an update regarding chemical
assays received from samples recovered from the outstanding assays from the 2024 drilling
campaign at the Overland Project.
The assay results largely conform with down hole gamma responses and in-field pXRF
measurements for contained uranium. This provides continued confidence that these immediate
field-based measurements can guide us to a discovery at Overland as AR3’s drilling progresses.
The results also confirm mineralisation extends to the Western Margin Target Zone (Figure 2)
which strengthens the highly prospective nature of this area. Additional drilling to follow up the
strike extension of this mineralisation is planned for April 2025. .
The assay results also showed anomalous uranium content at the base of oxidation of the
sedimentary sequences intersected in drillholes and their contact with reduced sediments.
These results point to an active system of uranium precipitation from solution in oxidized
groundwaters, and meteoric waters, within the Overland Project area, further evidence of a
setting providing all the requisite elements required for the formation of sedimentary-hosted
uranium deposits.
Overland – Sedimentary hosted uranium prospectivity is supported by recent drilling and now
by the laboratory assays from its first 25 holes drilled in 2024. The area has yielded compelling
evidence supporting AR3’s initial geological model. Critical elements required for the formation
of a sedimentary-hosted uranium deposit have been identified at Overland, including:
• a uranium source rock,
• permeable sediments as migration pathways, and
• effective reductants acting as traps for uranium precipitation.
Overland now demonstrates potential for both near surface, calcrete-hosted uranium and
deeper, ISR-amenable deposits emphasising the value of the Company’s vast 4,000km2
exploration area in a frontier uranium play.
Figure 1: Project Location Plan with figure 2 inset shown
Figure 2: Section Location Plan showing 2024 drillholes with all assays now received (green) and pending assays from 2025
drilling (grey).
Figure 3: -Section A-A1 including new assays received for holes OV015 and OV016 along with previously reported assays 1.
See Figure 4 for OV002 infill drilling detail.
In relation to the disclosure of pXRF results in figures 3, 4 and 5, the Company cautions that
estimates of uranium elemental abundance from pXRF results should not be considered a proxy
for quantitative analysis of a laboratory assay result. Assay results are required to determine the
actual widths and grade of the mineralisation. The company uses an Olympus Vanta M Series
portable X-ray Fluorescence (pXRF) analyzer to screen Air Core drilling samples for mineralisation
prior to submitting samples to a commercial laboratory for assay. This provides an initial
understanding of the mineralisation distribution before sampling, ensuring submitted samples
are representative of the targeted mineralisation. While pXRF confirms the presence of
mineralisation, it does not accurately determine elemental concentrations due to limitations
such as a small analysis window, uneven distribution, shallow penetration depth, and irregular
surfaces. The pXRF results are indicative and the pXRF readings are subject to confirmation by
chemical analysis from an independent laboratory.
1
See ASX release: 13 February 2025
Figure 4: Section showing OV002 and infill holes with recent assays either side of OV024 and OV025.
Figure 5: Section B-B1
Next steps
The 2025 Overland drilling program continues with drill testing on EL6678 for paleochannel
uranium and the recently discovered near surface calcrete hosted uranium mineralisation 2.
Following on from drill testing targets within EL6678 the drill rig will move north to follow up the
strike extension of the Western Margin Target Zone. Drilling will be targeting the anomalous
uranium within holes OV012 and OV013 and the abundance of lignite horizons with associated
anomalous downhole natural gamma readings, all of which support the Western Margin Target
Zone as containing significant potential for uranium mineralisation.
Assays are expected from the first swing of the 2025 drill program in the coming weeks and results
will further inform AR3’s exploration.
2
Refer ASX release: 19 March 2025
The announcement has been authorised for release by the Board of Australian Rare Earths Limited.
For further information please contact:
Australian Rare Earths Limited
Travis Beinke
Managing Director and CEO
T: 1 300 646 100
Media Enquiries
Jessica Fertig
Tau Media
E: info@taumedia.com.au
Engage and Contribute at the AR3 investor hub: https://investorhub.ar3.com.au/
Competent Person’s Statement
The information in this report that relates to Exploration results is based on information compiled by Australian
Rare Earths Limited and reviewed by Mr Rick Pobjoy who is the Chief Technical Officer of the Company and a
member of the Australian Institute of Mining and Metallurgy (AusIMM). Mr Pobjoy has sufficient experience that
is relevant to the style of mineralisation, the type of deposit under consideration and to the activities undertaken
to qualify as a Competent person as defined in the 2012 edition of the “Australasian Code for Reporting of
Exploration Results, Mineral Resources and Ore Reserves”. Mr Pobjoy consents to the inclusion in this report of
the matters based on this information in the form and context in which it appears.
About Australian Rare Earths Limited
Australian Rare Earths (AR3) is an emerging diversified critical minerals company, strategically positioned to meet
the growing global demand for uranium and rare earth elements. The Company’s vast 4,000 km² Overland
Uranium Project in South Australia shows strong uranium discovery potential, with initial drilling identifying
opportunities for substantial near-surface and deeper deposits.
Simultaneously, AR3's Koppamurra Rare Earths Project in South Australia and Victoria has secured important
government support through a $5 million grant to accelerate development. With support from global advanced
industrial materials manufacturer, Neo Performance Materials, AR3 is progressing toward a Pre-Feasibility Study
and a demonstration facility, solidifying its role in diversifying global rare earth supply chains for the clean energy
transition. With strategic projects and strong government support, AR3 is poised for significant growth in the critical
minerals market.
JORC Table 1
Criteria
Sampling
techniques
Section 1 Sampling Techniques and Data
Explanation
Comment
Nature and quality of
Air Core drilling methods were used to obtain
samples from the Overland drilling program
sampling (e.g., cut
channels, random chips, or between October-December 2024 and JanuaryMarch 2025
specific specialised
industry standard
The following information details the Air Core drill
measurement tools
sampling process:
appropriate to the
minerals under
• All Air Core drill samples were collected from
investigation, such as
the rotary splitter mounted at the bottom of
down hole gamma sondes,
the cyclone into a pre‐numbered calico bag.
or handheld XRF
The samples were geologically logged at 1 m
instruments, etc). These
intervals.
examples should not be
taken as limiting the broad • Based on hole‐diameter, generic material
density and a 20% split on the cyclone
meaning of sampling.
samples averaged ~1.5‐2.5 kg in mass.
Include reference to
measures taken to
• Chip trays were used to collect a
ensure sample
representative sample for each 1m sample
representivity and the
interval for each hole.
appropriate calibration
• After the samples were collected within the
of any measurement
calico bags, they were screened for
tools or systems used.
anomalous gamma radiation using a
Aspects of the
handheld Ranger EXP survey meter (S/N
determination of
R318772) calibrated 23/09/2024 prior to
mineralisation that are
being geologically logged and tested with a
Material to the Public
pXRF at the drill site.
Report. In cases where
‘industry standard’ work
has been done this would
be relatively simple (e.g.,
‘reverse circulation drilling
was used to obtain 1 m
samples from which 3 kg
was pulverised to produce
a 30 g charge for fire
assay’). In other cases,
more explanation may be
required, such as where
there is coarse gold that
has inherent sampling
problems. Unusual
commodities or
mineralisation types (e.g.,
•
The gamma screening was conducted by
placing the handheld Ranger survey meter
~10cm from the calico sample for 5‐10sec and
noting the dose rate in µSv. If elevated dose
rates were detected the field crew was then
notified before any additional sample logging
was conducted and the anomalous reading
recorded in the geological log.
•
A handheld Olympus Vanta pXFR Analyser
(Model Vanta M Series S/N 842924) was used
to assess the geochemistry of the Air Core
samples in the field. The pXRF analysis
provided screening analysis to characterize
the sample lithology and full suite of
elements.
•
The pXRF sampling was analyzed through
the calico bag with a beam count time of 2030 sec beam 1 and 10 sec beam 2. One pXRF
analysis
submarine nodules) may
warrant disclosure
of detailed information.
per sample was performed.
•
Samples are laid on a workbench and
flattened to create a stable surface for the
pXRF. The pXRF is placed on the sample with
the beam down for the analysis.
•
All readings were taken at ambient
temperatures between 10 and 45 degrees
Celsius. The Olympus Vanta is rated
for continuous
operation
within
these temperatures.
•
Samples range from dry to wet, this is
dependent on which formation is
being intercepted and whether drilling
water has been injected.
•
A Uranium standard Oreas 121 (215 ppm U,
sourced from Mantra Resources
Nyota Prospect, Tanzania, which is a
Tabular Sandstone hosted deposit) was
used to verify the accuracy of the pXRF
before and after each analysis session.
•
The OREAS 121 standard was prepared using
an industry standard pXRF sample cup and
analyzed for 20-30 sec on beam 1 and 10 Sec
on beam 2.
•
A silica blank is used to monitor the
accumulation of contamination on the lens
of the pXRF. Analysis of the blank
is undertaken before and after each analysis
session.
•
Review of pXRF standard and blank data is
checked to ensure the pXRF is operating
correctly before and after each session.
•
Samples were selected for assay at the end
of the hole based on geology, pXRF, and
natural downhole gamma response.
•
Field duplicates were taken at a rate of
~1:40 and inserted blindly into the sample
batches.
•
Field Standards were taken at a rate of ~1:40
and inserted blindly into the samples batches.
•
Samples were submitted to Bureau Veritas
in Adelaide for analysis. The sample
weights were recorded (wet and dry) and
samples
were oven dried at 105 degrees for a
minimum of 24 hours. The samples were
secondary crushed to 3 mm fraction and then
pulverised to 90% passing 75 µm. Excess
residue was maintained for storage while the
rest of the sample placed in 8x4 packets and
sent to the central weighing laboratory. The
samples were submitted for analysis using
Mixed Acid Digest – Lithium Borate Fusion
ICP‐MS method (BV Code SC302) for Ag (0.1),
Al (100), As (1), Ba (1), Be
(0.5), Bi (0.1), Ca (100), Cd (0.5), Ce (0.1), Co
(1), Cr (10), Cs (0.1), Cu (1), Dy (0.05), Er
(0.05), Eu (0.05), Fe (100), Ga (0.2), Gd (0.2),
Hf (0.2), Ho (0.02), In (0.05), K (100), La (0.5),
Li (0.5), Lu (0.02), Mg (100), Mn (2), Mo (0.5),
Na (100), Nb (0.5), Nd (0.05), Ni (2), P (100),
Pb (1), Pr (0.2), Rb (0.2), Re (0.1), S (50), Sb
(0.1), Sc (1), Se (5), Si (100), Sm (0.05), Sn (1),
Sr (0.5), Ta (0.1), Tb (0.02), Te (0.2), Th (0.1),
Ti (50), Tl (0.1), Tm (0.2), U (0.1), V (5), W
(0.5), Y (0.1), Zn (2), Zr (1), Yb (0.05)
• Select samples, often at the bottom of the
thought
to
be
weathered
holes
basement/saprolite material were also
analyzed for gold using Lead collection Fire
Assay AAS (BV Code FA001)
• A laboratory repeat was taken at ~ 1 in 21
samples;
• Commercially obtained standards were
inserted by the laboratory at a rate of ~ 1 in
9 into the sample sequence.
•
After the hole was drilled to completion a
Reflex EZ Gamma logging tool (serial number
GAM‐043) rented from Imdex, and operated
by the drilling crew was run down the hole,
inside the rods/innertube to log the natural
gamma response of the sediments. The
gamma tool was last calibrated by Imdex on
October 9th 2024 as noted in the provided
Certificate of Conformance.
•
The survey was run in and out of the hole at a
speed of no more than 10m/min and the
downhole speed was reviewed after the
survey.
•
The up (out) survey was then used to plot
sections, after reviewing both in and out
gamma surveys.
•
Before each downhole gamma survey the
Reflex EZ Gamma logging tool was checked
with a EZ‐Gamma confidence checker by AR3
staff (S/N 025). The confidence checker was
last calibrated 29/08/24.
•
Using the EZ‐Gamma confidence checker at
the start of each run allows the gamma tool
to be checked ensuring it is within
specifications and the tool has not been
damaged or faulty providing confidence an
accurate gamma reading is collected for each
hole.
The check is completed by first running the
gamma tool for ~3-5min to measure
Background Gamma (BKG) in cps. A second
survey is then conducted after sliding the EZ‐
Gamma Confidence checker (Jig serial number
025) over the gamma probe and measuring a
Sleeve Response (SR) in cps. The BKG value is
subtracted from the SR value which provides a
Calculated Sleeve Response (CSR) value in cps.
The CSR is then compared to the Expected
Value (EV) of the gamma checker which is
certified to be 636 cps. A resulting pass value=
636 cps +/‐ 10 % and required before the
survey tool is confirmed as operating within
expected limits.
The formula used for checking the gamma tool
is as follows;
CSR= SR-BKG
CSR is compared to the EV of the confidence
checker which is certified to 636cps (for jig
serial number 025) +/- 10% (for pass value of
573-700cps).
•
•
•
•
•
After the gamma survey is completed the
data is uploaded to the Imdex hub IQ portal
(https://iq.imdexhub.com) from the rig via
satellite internet and available for review.
•
The Fairview uranium occurrence shown on
maps within this report is based on reported
SA Geodatabase Reference sample #152296
(Explorers sample 45835) sourced from the
SA Geodatabase available on SARIG
https://minerals.sarig.sa.gov.au/RockSamp
leDetails.aspx?SampleNo=45835
• Sample #152296 was collected by A.F. Crooks
on 20/08/1984 and the sample was analyzed
by XRF. Details on the lab or XRF
device were not specified.
Drilling
techniques
Drill type (e.g., core,
reverse circulation, open‐
•
hole hammer, rotary air
blast, auger, Bangka,
sonic, etc) and details
•
(e.g., core diameter, triple
or standard tube, depth of
diamond tails, face‐
sampling bit, or other type,
whether core is oriented and
if so, by what method, etc).
•
•
•
Drill sample
recovery
Method of recording and
assessing core and chip
sample recoveries and
results assessed.
Measures taken to
maximise sample recovery
and ensure representative
nature of the samples.
Whether a relationship
exists between sample
recovery and grade and
whether sample bias may
have occurred due to
preferential loss/gain of
fine/coarse material.
•
•
•
•
•
•
•
•
Drilling was completed using a Wallis “Mantis
200”Air Core drill rig with an onboard Sullair
compressor (560cfm @ 200psi).
Aircore drilling is a form of reverse circulation
drilling where the sample is collected at
the face and returned inside the inner tube.
The drill cuttings are removed by injection of
compressed air into the hole via the annular
area between the inner tube and the drill rod.
Aircore drill rods used were 3 m long.
NQ diameter (76 mm) drill bits and rods were
used.
All aircore drill holes were vertical with depths
varying between ~90 m and 200 m.
Drill sample recovery for Air Core drilling is
monitored by recording sample condition
descriptions where ‘Poor’ to ‘Very Poor’ were
used to identify any samples recovered which
were potentially not representative of the
interval drilled.
A comment was included where water
injection was required to recover the sample
from a particular interval. The use of water
injection can potentially bias a sample.
Minimal water injection was required during
this drilling program and used sparingly.
Overall no consistent/significant loses of
sample material was observed.
The rotary splitter was set to an approximate
20% split, which produced approximately
1.5‐2.5 kg sample for each meter interval.
The 1.5‐2.5 kg sample was collected in a pre‐
numbered calico bag and the remaining 80%
(5 kg to 8 kg) was disposed directly into the
sump as drilling progressed.
At the end of each drill rod, the drill string is
cleaned by blowing down with air to remove
any clay and silt potentially built up in the
sample pipes and cyclone.
The relationship (if any) between sample
recovery and grade is unknown
No sample recovery information was reported
in historical reports relating to
historical drilling within this release.
Logging
Whether core and chip
•
samples have been
geologically and
geotechnically logged to a
level of detail to support
appropriate Mineral
Resource estimation, mining •
studies and metallurgical
studies. Whether logging is
qualitative or quantitative in
nature. Core (or costean,
channel, etc) photography.
The total length and
percentage of the relevant •
intersections logged.
•
Sub‐sampling
techniques
and sample
preparation
If core, whether cut or
sawn and whether
quarter, half or all cores
taken.
If non‐core, whether
riffled, tube sampled,
rotary split, etc and
whether sampled wet or
dry.
For all sample types, the
nature, quality, and
appropriateness of the
sample preparation
technique.
Quality control
procedures adopted for
all sub‐sampling stages to
maximise representivity
of samples.
Measures taken to ensure
that the sampling is
representative of the in‐
situ material collected,
including for instance
results for field
duplicate/second‐half
sampling.
All Air Core samples collected in calico bags
were logged for lithology, colour, cement type,
hardness, percentage rock estimate, and any
relevant comments such as moisture, sample
condition, evidence of reducing or oxidizing
conditions, and vegetation/organic material.
Geological logging data for all drill holes was
qualitatively logged onto Microsoft Excel
spreadsheet using a field laptop with validation
rules built into the spreadsheet including
specific drop‐ down menus for each variable.
The data was uploaded to the Australian Rare
Earths Azure Data Studio database.
Every drill hole was logged in full and logging
was undertaken with reference to a drilling
template with codes prescribed and guidance
to ensure consistent and systematic data
collection.
The density drilling is not sufficient to support
consideration of resource estimation, or mining
and no geotechnical logging was completed.
• 1m Air Core sample interval was
homogenised within the cyclone and the
rotary splitter was set to an approximate
20% split producing around 1.5‐2.5 kg
sample for each metre interval.
• The 1.5‐2.5kg sample was collected in a pre‐
numbered calico bag and the 80% (5 kg to 8
kg) portion was disposed directly into the
sump as drilling progressed.
• Duplicates were generally taken within
intervals which indicated potential for
anomalous U mineralization based on
geology, pXRF, and gamma signature. These
duplicate samples were collected by splitting
the 1m interval by emptying the sample on
to a table, mixing and splitting into 1/8th
subsamples and randomly assigning 4 of the
splits into the duplicate and 4 remaining as
the primary.
• The 1.5‐2.5 kg sample collected in the calico
bag was logged by the geologist onsite.
• Approximately 10‐20g of sample material
from each for each 1m calico sample placed
in a chip tray.
• The logged calico samples were scanned
with a pXRF onsite through the calico bag.
• At the end of the drillhole samples were
Whether sample sizes are
appropriate to the grain
size of the material being
sampled.
selected for analysis.
• Samples selected for analysis were placed in
polyweave bags labelled with the sample
number, From‐To interval, and Hole ID, then
segregated into bulka bags for transport to
the lab for analysis.
• No correction factors were applied to pXRF
results.
• Field duplicates of all the samples were
completed at a frequency of ~1 in 40
samples. Field standards were inserted into
the sample sequence at a frequency of
~1:40. Standard reference Material (SRM)
samples were inserted into the sample
batches at a frequency rate of 1 per 10
samples by the laboratory and a repeat
sample was taken at a rate of 1 per 21
samples.
• An on‐site geologist oversaw the sampling
and logging process and selected samples for
analysis based on the logging descriptions
Pxrf analysis, and downhole gamma
response.
Quality of
assay data
and
laboratory
tests
The nature, quality and
appropriateness of the
assaying and laboratory
procedures used and
whether the technique is
considered partial or total.
For geophysical tools,
spectrometers, handheld
XRF instruments, etc, the
parameters used in
determining the analysis
including instrument make
and model, reading times,
calibrations factors
applied and their
derivation, etc.
Nature of quality control
procedures adopted (e.g.,
standards, blanks,
duplicates, external
laboratory checks) and
whether acceptable levels
of accuracy (i.e., lack of
•The detailed geological logging of samples
provides lithology (sand/clay component)
•The 1.5 kg air core samples were assayed by
Bureau Veritas laboratory in Wingfield, Adelaide,
South Australia, which is considered the Primary
laboratory.
•The samples will be initially oven dried at 105
degrees Celsius for 24 hours. Samples will be
secondary crushed to 3 mm fraction and the
weight recorded. The sample will then be
pulverised to 90% passing 75 µm. Excess residue
will be maintained for storage while the rest of
the sample is placed in 8x4 packets and sent to
the central weighing laboratory.
•All weighed samples will then be analysed using
the Multiple Elements Fusion/Mixed Acid Digest
analytical method;
•ICP Scan (Mixed Acid Digest – Lithium Borate
Fusion) Samples are digested using a mixed acid
digest and also fused with Lithium Borate to
ensure all elements are brought into solution. The
bias) and precision have
been established.
digests are then analysed for the following
elements (detection Limits shown): Al (100) As (1)
Ba (1) Be (0.5) Ca(100) Ce (0.1) Co (1) Cr (10) Dy
(0.05) Er (0.05) Eu(0.05) Fe(100) Gd (0.2) Ho
(0.02) K (100) La (0.5) Lu (0.02) Mg (100) Mn (2)
Na (100) Nd (0.05) Ni (2) Pr (0.2) S (50) Sc (1) Si
(100) Sm(0.05) Sr (0.5) Th (0.1) Ti (50) Tm (0.2) U
(0.1) V (5) Y (0.1) Yb (0.05) Zr (1)
•
Select samples that were deemed likely to be
of basement lithology (or saprolite) were also
analyzed for Au Fire Assay with a detection
limit of (0.01)
•Field duplicates were collected and submitted at
a frequency of ~1 per 40 samples.
•
Bureau Veritas will complete its own internal
QA/QC checks that include a Laboratory
repeat every 21st sample and a standard
reference sample every 9th sample prior to
the results being released.;
•
Australian Rare Earths submitted field
standards at a frequency of ~1:40
samples.
•
Australian Rare Earths inserted field blanks at
a frequency of ~1:40 samples.
The adopted QA/QC protocols are acceptable for
this stage of test work. The sample preparation
and assay techniques used are industry standard
and provide a total analysis.
Historical data referenced within this report is
detailed below;
•
The Fairview uranium occurrence an is based
on reported SA Geodatabase Reference
sample #152296 (Explorers sample 45835)
sourced from the SA Geodatabase available
on SARIG
(https://minerals.sarig.sa.gov.au/RockSample
Details.aspx?SampleNo=45835)
Sample #152296 was collected by A.F. Crooks
on 20/08/1984 and the sample was analyzed
by XRF, details on the lab or XRF device were
not specified.
Verification
of sampling
and assaying
The verification of
significant intersections by
either independent or
alternative company
personnel.
The use of twinned holes.
Documentation of primary
data, data entry
procedures, data
verification, data storage
(physical and electronic)
protocols.
Discuss any adjustment to
assay data.
Location of
data points
Accuracy and quality of
surveys used to locate drill
holes (collar and down‐
hole surveys), trenches,
mine workings and other
locations used in Mineral
Resource estimation.
Specification of the grid
system used.
Quality and adequacy of
topographic control.
All results are checked by the company’s
Chief Technical Officer.
• Field based geological logging for drill holes was
entered directly into an Excel spreadsheet
format with validation rules built into the
spreadsheet including specific drop‐down
menus for each variable. This digital data was
then uploaded to the Australian Rare Earths
Azure Data Studio database.
• Assay data will be received in digital format
from the laboratory and uploaded to
Australian Rare Earths Azure Data Studio
database.
•
Field and laboratory duplicate data pairs of
each batch will be plotted to identify potential
quality control issues.
•
Standard Reference Material sample results
will be checked from each sample batch to ensure
they are within tolerance (<3SD) and that there is
no bias.
• U3O8 is the industry accepted form for reporting
Uranium. An oxide factor for U3O8 of 1.1793
was used for reporting throughout this report.
• All maps are in GDA94/MGA zone 54.
• All overland coordinate information was
collected using handheld GPS utilizing
GDA 1994, Zone 54. While spatial
location is expected to be recovered
within 3 – 5 m, it is possible that the
elevation can be as much as 10 m out
with respect to the currently established
geoid.
• Drillhole RL has been corrected using An
Australian wide SRTM. The 1 second
SRTM Level 2 Derived Smoothed Digital
Elevation Model (DEM‐S) is derived from
the 2000 SRTM. The DEM‐S has a ~30m
grid which has been adaptively
smoothed to improve the representation
of the surface shape and is the preferred
method for shape and vertical accuracy
from STRM products. The smoothing
process estimated typical improvements
in the order of 2‐3 m. This would make
the DEM‐S accuracy to be of
approximately 5 m.
•
Data spacing
and
distribution
Orientation
of data in
relation to
geological
structure
Data spacing for reporting
of Exploration Results.
Whether the data spacing,
and distribution is
sufficient to establish the
degree of geological and
grade continuity
appropriate for the
Mineral Resource and Ore
Reserve estimation
procedure(s) and
classifications applied.
Whether sample
compositing has been
applied.
Whether the orientation of
sampling achieves
unbiased sampling of
possible structures and the
extent to which this is
known, considering the
deposit type.
If the relationship between
the drilling orientation and
the orientation of key
mineralised structures is
considered to have
introduced a sampling
bias, this should be
assessed and reported if
material.
• Locations of Overland drill holes are
reported within the appendices of this
report.
•
No geological or grade continuity estimations
are being determined from the Overland
drilling data.
•
Share your feedback
Discover