Overland Initial Drilling Confirms Strong Uranium Potential
Released
Released
Announcement PDF
13 November 2024
Overland Project: Initial drilling confirms
strong uranium potential
Highlights:
•
Initial drilling progress: First four Air Core (AC) drill holes, totaling 640 meters,
completed at the first target of AR3’s Overland Project, a new frontier uranium play
in South Australia.
•
Target stratigraphy intersected: All holes intersected thick sequences of Murray
group stratigraphy containing interbedded sands and clays. These display all the
attributes required for pathways for uranium bearing groundwaters and for hosting
uranium mineralisation.
•
Preliminary results indicate presence of uranium: All drill holes have returned
anomalous downhole natural gamma readings and portable X-ray fluorescence
(pXRF) 1 results, indicating the presence of uranium and confirming the area’s
prospectivity.
•
Next steps: Currently drilling Target 2 focusing on the Murray Group and Renmark
Group sediments. Planning Target 1 follow-up drilling.
•
Engage with this announcement at the AR3 investor hub.
AR3 Managing Director and CEO, Travis Beinke, said:
“Today’s announcement signals proof-of-concept success within the first four holes drilled
targeting uranium within this frontier uranium region. Positive results from our first series of holes
at the Overland Uranium project’s initial target, validates our geological model for the potential
for sedimentary-hosted uranium deposits within the project area.
1
Cautionary Statement- In relation to the disclosure of pXRF results, the Company cautions that estimates of
uranium elemental abundance from pXRF results should not be considered a proxy for quantitative analysis of a
laboratory assay result. Assay results are required to determine the actual widths and grade of the mineralisation. The
company uses an Olympus Vanta M Series portable X-ray Fluorescence (pXRF) analyzer to screen Air Core drilling
samples for mineralization prior to submitting samples to a commercial laboratory for assay. This provides an initial
understanding of the mineralization distribution before sampling, ensuring submitted samples are representative of
the targeted mineralization. While pXRF confirms the presence of mineralization, it does not accurately determine
elemental concentrations due to limitations such as a small analysis window, uneven distribution, shallow
penetration depth, and irregular surfaces. The pXRF results are indicative and the pXRF readings are subject to
confirmation by chemical analysis from an independent laboratory. The Olympus Vanta M Series (S/N 842924) pXRF
was last inspected on 11/07/2023 by SA Radiation Pty and checked against known standard reference material daily.
Our inaugural ~5,000 meter drilling program continues with initial high-priority targets still to be
tested. Based on the results from Target 1’s first four holes, we are planning follow-up drilling with
both infill and step-out locations identified and drilling set to commence there later this month.
Given Overland’s substantial ~3,000km2 project area with numerous high-priority targets to test
over time, achieving such encouraging results at our first target in this greenfield exploration
venture is outstanding and has exceeded our expectations for these initial holes.
I’m excited to assess additional drill results as the program continues through the balance of 2024
and into early 2025.”
Australian Rare Earths Limited (ASX: AR3) is pleased to announce initial drilling results from the
Overland Uranium Project. Spanning 3,000km2, the Project is situated in a region with strong
potential for In-Situ Recovery (ISR) amenable, sedimentary-hosted uranium deposits. AR3
believes the paleochannel sediments of the Renmark Group and Murray Group sediments (Eyre
and Namba equivalents) offer significant potential for uranium discovery.
Drilling at the Overland Project recently commenced following the grant of two Exploration
Program for Environment Protection and Rehabilitation (EPEPR) approvals, opening up ~770 km²
(25%) of the total project area for immediate exploration (Figure 1).
Overland – Sedimentary Hosted Uranium Prospectivity supported by recent drilling
Initial drilling at the Overland Project has provided compelling evidence supporting AR3’s initial
geological model (Table 1). The five critical elements required for the formation of a sedimentaryhosted uranium deposit have been identified, including a uranium source rock, permeable
sediments as migration pathways, and effective reductants acting as traps for uranium
precipitation.
This reinforces AR3’s confidence in the Overland Project’s potential for significant uranium
mineralisation.
Table 1- summary of key components required for uranium mineralisation.
Figure 1: Overland project with approved work areas, regional geology.
AR3 is initially pursuing three highly prospective drill targets within the northwest of EL7001
(Figure 2), starting with Target 1, which was tested with the first four drill holes (OV001-OV004).
This area was selected to assess a prominent north-south fault feature, the interpreted felsic
basement as a potential uranium source, and the permeable sands of the Renmark and Murray
Groups, which have been identified as prospective for hosting uranium mineralisation
Drilling within Target 1, at 800-meter drill spacing, intersected Murray Group sediments, revealing
zones with anomalous gamma responses and elevated pXRF uranium readings. These
sequences are effectively bounded by confining clay layers above and below, with multiple zones
of permeability identified (see Table 2 and Figures 3 & 4) ideal settings for ISR amenable uranium
deposits.
Figure 2: Overland Targets showing recent drilling relative to airborne magnetics, faulting, and interpreted felsic intrusives.
Table 2: Select holes from the Overland project containing intersections and lithologies.
Hole ID
To
(m)
93
Width
(m)
1
lithology
Summary Description
OV001
From
(m)
92
Reduced
sands
OV001
107.5
108
0.5
Clay
OV002
79.5
82.5
3
Reduced
sands and
Lignite
OV002
110
111
1
Clay
OV003
84.5
86.0
1.5
Clay
OV003
102
109
7
Oxidized
sands
OV004
84
86
2
Clay
Anomalous gamma and pXRF U associated with
interbedded clays and silty clays at the base of
the upper package of permeable sediments
Anomalous gamma at base of the lower package
of permeable sediments
Anomalous gamma (peak 570 counts per second
(cps)) and pXRF U associated with a lignite
horizon and the reduced sands surrounding it, in
the upper package of permeable sediments
Anomalous gamma (peak 333 cps) at the base of
the lower package of permeable sediments
Anomalous gamma (peak 394 cps) at base of the
upper package of permeable sediments.
An oxidised sand zone bounded by thin clay
layers, the gamma response for which is
interpreted as limbs of a classic roll front,
potentially occurring between OV003 and the
reduced sediments in holes OV002 and/or OV004.
Anomalous gamma (peak 288 cps) with a
coinciding pXRF U anomaly at the base of the
upper package of permeable sediments.
Figure 3: Cross section A-A1 showing OV001-OV004 lithology, pXRF U (ppm), Gamma (cps) and Interpreted roll front.
Figure 4: Anomalous downhole pXRF and natural gamma logs over target intervals.
Next steps
The first batch of drill samples will be submitted for assay in November with results expected late
2024.
Drilling is to continue in the northwest of EL7001 (Figure 2) targeting key structural features,
including faulting and zones where historic drillholes intersected Renmark Group stratigraphy.
Thick sequences of interbedded sands and clays within the Murray and Renmark Group will be a
primary focus, as they are considered prospective for hosting uranium mineralisation.
Based on initial results, follow up drilling at Target 1 to test the interpreted roll front
mineralisation and the remainder of the target area with an east-west traverse covering the
prominent north-south fault feature and the interpreted felsic basement - a potential uranium
source.
The announcement has been authorised for release by the Board of Australian Rare Earths Limited.
For further information please contact:
Australian Rare Earths Limited
Travis Beinke
Managing Director and CEO
T: 1 300 646 100
Media Enquiries
Jessica Fertig
Tau Media
E: info@taumedia.com.au
Engage and Contribute at the AR3 investor hub: https://investorhub.ar3.com.au/
Competent Person’s Statement
The information in this report that relates to Exploration results is based on information compiled by Australian
Rare Earths Limited and reviewed by Mr Rick Pobjoy who is the Chief Technical Officer of the Company and a
member of the Australian Institute of Mining and Metallurgy (AusIMM). Mr Pobjoy has sufficient experience that
is relevant to the style of mineralisation, the type of deposit under consideration and to the activities undertaken
to qualify as a Competent person as defined in the 2012 edition of the “Australasian Code for Reporting of
Exploration Results, Mineral Resources and Ore Reserves”. Mr Pobjoy consents to the inclusion in this report of
the matters based on this information in the form and context in which it appears.
About Australian Rare Earths Limited
Australian Rare Earths is committed to the timely exploration and development of its 100% owned, flagship
Koppamurra Project, located in the new Koppamurra rare earths Province in southeastern South Australia and
western Victoria. Koppamurra is a prospective ionic clay hosted rare earth deposit, rich in all the elements
required in the manufacture of rare earth permanent magnets which are essential components in electric
vehicles, wind turbines and domestic appliances. In addition, AR3 is actively reviewing other potential
prospective areas which may also host uranium and ionic clay hosted rare earth deposits throughout Australia.
The Company is focused on executing a growth strategy that aims to position AR3 as an independent and
sustainable source of energy transition metals, playing a pivotal role in the global transition to a green economy.
JORC Table 1
Criteria
Sampling
techniques
Section 1 Sampling Techniques and Data
Explanation
Comment
Nature and quality of
Air Core drilling methods were used to obtain
sampling (e.g., cut
samples from the Overland drilling program.
channels, random chips, or
specific specialised
The following information details the Air Core drill
industry standard
sampling process:
measurement tools
• All Air Core drill samples were collected from
appropriate to the
the rotary splitter mounted at the bottom of
minerals under
the cyclone into a pre-numbered calico bag.
investigation, such as
The samples were geologically logged at 1 m
down hole gamma sondes,
intervals.
or handheld XRF
• Based on hole-diameter, generic material
instruments, etc). These
density and a 20% split on the cyclone
examples should not be
samples averaged ~1.5-2.5 kg in mass.
taken as limiting the broad
meaning of sampling.
• Chip trays were used to collect a
Include reference to
representative sample for each 1m sample
measures taken to
interval for each hole.
ensure sample
• After the samples were collected within the
representivity and the
calico bags, they were screened for
appropriate calibration
anomalous gamma radiation using a
of any measurement
handheld Ranger EXP survey meter (S/N
tools or systems used.
R318772) calibrated 23/09/2024 prior to
Aspects of the
being geologically logged and tested with a
determination of
pXRF at the drill site.
mineralisation that are
Material to the Public
• The gamma screening was conducted by
Report. In cases where
placing the handheld Ranger survey meter
‘industry standard’ work
~10cm from the calico sample for 5-10sec
has been done this would
and noting the dose rate in µSv. If elevated
be relatively simple (e.g.,
dose rates were detected the field crew was
‘reverse circulation drilling
then notified before any additional sample
was used to obtain 1 m
logging was conducted and the anomalous
samples from which 3 kg
reading recorded in the geological log.
was pulverised to produce
• A handheld Olympus Vanta pXFR Analyser
a 30 g charge for fire
was used to assess the geochemistry of the
assay’). In other cases,
Air Core samples in the field. The pXRF
more explanation may be
analysis provided screening analysis to
required, such as where
characterize the sample lithology and full
there is coarse gold that
suite.
has inherent sampling
problems. Unusual
• The pXRF sampling was analized through
commodities or
the calico bag with a beam count time of 30
mineralisation types (e.g.,
sec beam 1 and 10 sec beam 2.
submarine nodules) may
warrant disclosure
of detailed information.
• Samples were selected for assay at the end of
the hole based on geology, pXRF, and
natural downhole gamma response.
• Field duplicates were taken at a rate of ~1:40
and inserted blindly into the sample batches.
• Field Standards were taken at a rate of ~1:40
and inserted blindly into the samples batches.
• Samples were submitted to Bureau Veritas in
Adelaide for analysis. The sample weights
were recorded (wet and dry) and samples
were oven dried at 105 degrees for a
minimum of 24 hours. The samples were
secondary crushed to 3 mm fraction and
then pulverised to 90% passing 75 µm.
Excess residue was maintained for storage
while the rest of the sample placed in 8x4
packets and sent to the central weighing
laboratory. The samples were submitted for
analysis using Mixed Acid Digest – Lithium
Borate Fusion ICP-MS method (BV Code
SC302) for Ag (0.1), Al (100), As (1), Ba (1), Be
(0.5), Bi (0.1), Ca (100), Cd (0.5), Ce (0.1), Co
(1), Cr (10), Cs (0.1), Cu (1), Dy (0.05), Er
(0.05), Eu (0.05), Fe (100), Ga (0.2), Gd (0.2),
Hf (0.2), Ho (0.02), In (0.05), K (100), La (0.5),
Li (0.5), Lu (0.02), Mg (100), Mn (2), Mo (0.5),
Na (100), Nb (0.5), Nd (0.05), Ni (2), P (100),
Pb (1), Pr (0.2), Rb (0.2), Re (0.1), S (50), Sb
(0.1), Sc (1), Se (5), Si (100), Sm (0.05), Sn (1),
Sr (0.5), Ta (0.1), Tb (0.02), Te (0.2), Th (0.1),
Ti (50), Tl (0.1), Tm (0.2), U (0.1), V (5), W
(0.5), Y (0.1), Zn (2), Zr (1), Yb (0.05)
• Select samples were also analyzed for gold
using Lead collection Fire Assay AAS (BV Code
FA001)
• A laboratory repeat was taken at ~ 1 in 21
samples;
• Commercially obtained standards were
inserted by the laboratory at a rate of ~ 1 in
9 into the sample sequence.
•
After the hole was drilled to completion a
Reflex EZ Gamma logging tool (serial number
GAM-043) rented from Imdex, and operated
by the drilling crew was run down the hole,
inside the rods/innertube to log the natural
gamma response of the sediments. The
gamma tool was last calibrated by Imdex on
October 9th 2024 as noted in the provided
Certificate of Conformance.
•
The survey was run in and out of the hole at a
speed of no more than 10m/min and the
downhole speed was reviewed after the
survey.
•
The up (out) survey was then used to plot on
sections, after reviewing both in and out
gamma surveys.
•
Before each downhole gamma survey the
Reflex EZ Gamma logging tool was checked
with a EZ-Gamma confidence checker by AR3
staff (S/N 025). The confidence checker was
last calibrated 29/08/24.
•
Using the EZ-Gamma confidence checker at
the start of each run allows the gamma tool
to be checked ensuring it is within
specifications and the tool has not been
damaged or faulty providing confidence an
accurate gamma reading is collected for each
hole.
•
The check is completed by first running the
gamma tool for 5min to measure background
gamma, then a second survey after sliding
the EZ-Gamma Confidence checker over the
gamma probe and subtracting the
background. The resulting pass value of ~600
cps +/- 5% is required before the survey tool
is confirmed as operating within expected
limits.
•
After the gamma survey is completed the
data is uploaded to the Imdex hub IQ portal
(https://iq.imdexhub.com) from the rig via
satellite internet and available for review.
•
The Fairview uranium occurrence shown on
maps within this report is based on reported
SA Geodatabase Reference sample #152296
(Explorers sample 45835) sourced from the
SA Geodatabase available on SARIG
https://minerals.sarig.sa.gov.au/RockSamp
leDetails.aspx?SampleNo=45835
Drilling
techniques
Drill type (e.g., core,
reverse circulation, openhole hammer, rotary air
blast, auger, Bangka,
sonic, etc) and details
(e.g., core diameter, triple
or standard tube, depth of
diamond tails, facesampling bit, or other
type, whether core is
oriented and if so, by what
method, etc).
Drill sample
recovery
Method of recording and
assessing core and chip
sample recoveries and
results assessed.
Measures taken to
maximise sample recovery
and ensure representative
nature of the samples.
Whether a relationship
exists between sample
recovery and grade and
whether sample bias may
have occurred due to
preferential loss/gain of
fine/coarse material.
• Sample #152296 was collected by A.F. Crooks
on 20/08/1984 and the sample was
analyzed by XRF. Details on the lab or XRF
device were not specified.
Drilling was completed using a Wallis
“Mantis 200”Air Core drill rig with an
onboard Sullair compressor (560cfm @
200psi).
• Aircore drilling is a form of reverse
circulation drilling where the sample is
collected at the face and returned inside the
inner tube. The drill cuttings are removed by
injection of compressed air into the hole via
the annular area between the inner tube and
the drill rod.
• Aircore drill rods used were 3 m long.
• NQ diameter (76 mm) drill bits and rods were
used.
• All aircore drill holes were vertical with
depths varying between ~140 m and 200 m.
•
•
•
•
•
•
•
Drill sample recovery for Air Core drilling is
monitored by recording sample condition
descriptions where ‘Poor’ to ‘Very Poor’ were
used to identify any samples recovered
which were potentially not representative of
the interval drilled.
A comment was included where water
injection was required to recover the sample
from a particular interval. The use of water
injection can potentially bias a sample.
Minimal water injection was required during
this drilling program and used sparingly.
No significant loses of sample material was
observed.
The rotary splitter was set to an approximate
20% split, which produced approximately
1.5-2.5 kg sample for each meter interval.
The 1.5-2.5 kg sample was collected in a prenumbered calico bag and the remaining 80%
(5 kg to 8 kg) was disposed directly into the
sump as drilling progressed.
At the end of each drill rod, the drill string is
cleaned by blowing down with air to remove
any clay and silt potentially built up in the
Logging
Sub-sampling
techniques
and sample
preparation
sample pipes and cyclone.
• The relationship (if any) between sample
recovery and grade is unknown
• No sample recovery information was
reported in historical reports relating to
historical drilling within this release.
Whether core and chip
• All Air Core samples collected in calico bags
samples have been
were logged for lithology, colour, cement
geologically and
type, hardness, percentage rock estimate,
geotechnically logged to a
sorting, and any relevant comments such as
level of detail to support
moisture, sample condition, evidence of
appropriate Mineral
reducing or oxidizing conditions, and
Resource estimation,
vegetation/organic material.
mining studies and
• Geological logging data for all drill holes was
metallurgical studies.
qualitatively logged onto Microsoft Excel
Whether logging is
spreadsheet using a field laptop with
qualitative or quantitative
validation rules built into the spreadsheet
in nature. Core (or
including specific drop- down menus for each
costean, channel, etc)
variable. The data was uploaded to the
photography.
Australian Rare Earths Azure Data Studio
The total length and
database.
percentage of the relevant • Every drill hole was logged in full and logging
intersections logged.
was undertaken with reference to a drilling
template with codes prescribed and guidance
to ensure consistent and systematic data
collection.
• The detail of logging is not sufficient to
support consideration of resource estimation,
mining, or metallurgical studies and no
geotechnical logging was completed.
If core, whether cut or
sawn and whether
quarter, half or all cores
taken.
If non-core, whether
riffled, tube sampled,
rotary split, etc and
whether sampled wet or
dry.
For all sample types, the
nature, quality, and
appropriateness of the
sample preparation
technique.
Quality control
procedures adopted for
• 1m Air Core sample interval was
homogenised within the cyclone and the
rotary splitter was set to an approximate
20% split producing around 1.5-2.5 kg
sample for each metre interval.
• The 1.5-2.5kg sample was collected in a
pre-numbered calico bag and the 80% (5 kg
to 8 kg) portion was disposed directly into
the sump as drilling progressed.
• Duplicates were generally taken within
intervals which indicated potential for
anomalous U mineralization based on
geology, pXRF, and gamma signature. These
duplicate samples were collected by splitting
the 1m interval by emptying the sample on
to a table, mixing and splitting into 1/8th
all sub-sampling stages to
maximise representivity
of samples.
Measures taken to ensure
that the sampling is
representative of the insitu material collected,
including for instance
results for field
duplicate/second-half
sampling.
Whether sample sizes are
appropriate to the grain
size of the material being
sampled.
Quality of
assay data
and
laboratory
tests
subsamples and randomly assigning 4 of the
splits into the duplicate and 4 remaining as
the primary.
• The 1.5-2.5 kg sample collected in the calico
bag was logged by the geologist onsite.
• Approximately 10-20g of sample material
from each for each 1m calico sample placed
in a chip tray.
• The logged calico samples were scanned
with a pxrf onsite through the calico bag.
• At the end of the drillhole samples were
selected for analysis.
• Samples were placed in polyweave bags
labelled with the sample number, From-To
interval, and Hole ID, then segregated into
bulka bags for transport either to the lab for
analysis or to AR3’s warehouse or similar
storage facility.
• Field duplicates of all the samples were
completed at a frequency of ~1 in 40
samples. Field standards were inserted into
the sample sequence at a frequency of
~1:40. Standard reference Material (SRM)
samples were inserted into the sample
batches at a frequency rate of 1 per 10
samples by the laboratory and a repeat
sample was taken at a rate of 1 per 21
samples.
A on site geologist oversaw the sampling
and logging process and selected samples
for analysis based on the logging
descriptions Pxrf analysis, and downhole
gamma.
• The detailed geological logging of samples
provides lithology (sand/clay component)
The nature, quality and
appropriateness of the
assaying and laboratory
• The 1.5 kg aircore samples were assayed by
procedures used and
Bureau Veritas laboratory in Wingfield, Adelaide,
whether the technique is
South Australia, which is considered the Primary
considered partial or total.
laboratory.
For geophysical tools,
spectrometers, handheld • The samples will be initially oven dried at
XRF instruments, etc, the 105 degrees Celsius for 24 hours. Samples will be
parameters used in
secondary crushed to 3 mm fraction and the
determining the analysis
weight recorded. The sample will then be
including instrument make pulverised to 90% passing 75 µm. Excess residue
and model, reading times, will be maintained for storage while the rest of
calibrations factors
applied and their
derivation, etc.
Nature of quality control
procedures adopted (e.g.,
standards, blanks,
duplicates, external
laboratory checks) and
whether acceptable levels
of accuracy (i.e., lack of
bias) and precision have
been established.
the sample is placed in 8x4 packets and sent to
the central weighing laboratory.
• All weighed samples will then be analysed
using the Multiple Elements Fusion/Mixed Acid
Digest analytical method;
• ICP Scan (Mixed Acid Digest – Lithium Borate
Fusion) Samples are digested using a mixed acid
digest and also fused with Lithium Borate to
ensure all elements are brought into solution. The
digests are then analysed for the following
elements (detection Limits shown): Al (100) As (1)
Ba (1) Be (0.5) Ca(100) Ce (0.1) Co (1) Cr (10) Dy
(0.05) Er (0.05) Eu(0.05) Fe(100) Gd (0.2) Ho
(0.02) K (100) La (0.5) Lu (0.02) Mg (100) Mn (2)
Na (100) Nd (0.05) Ni (2) Pr (0.2) S (50) Sc (1) Si
(100) Sm(0.05) Sr (0.5) Th (0.1) Ti (50) Tm (0.2) U
(0.1) V (5) Y (0.1) Yb (0.05) Zr (1)
•
Select samples that were deemed likely to be
of basement lithology (or saprolite) were also
analyzed for Au Fire Assay with a detection
limit of (0.01)
• Field duplicates were collected and
submitted at a frequency of ~1 per 40 samples.
• Bureau Veritas will complete its own internal
QA/QC checks that include a Laboratory repeat
every 21st sample and a standard reference
sample every 9th sample prior to the results
being released.;
• Australian Rare Earths submitted field
standards at a frequency of ~1:40 samples.
• Australian Rare Earths requested BV insert
blank washes at a frequency of 1:40 samples.
These blank washes were inserted in the sample
sequence behind samples which were thought to
be mineralized to ensure that no contamination
from higher grade samples was occurring.
Frequency of blank samples totaled ~1 in 40
samples.
The adopted QA/QC protocols are acceptable for
this stage of test work. The sample preparation
and assay techniques used are industry standard
and provide a total analysis.
Historical data referenced within this report is
detailed below;
The Fairview uranium occurrence an is based
on reported SA Geodatabase Reference
sample #152296 (Explorers sample 45835)
sourced from the SA Geodatabase available
on SARIG
(https://minerals.sarig.sa.gov.au/RockSample
Details.aspx?SampleNo=45835)
• Sample #152296 was collected by A.F. Crooks
on 20/08/1984 and the sample was analyzed
by XRF, details on the lab or XRF device were
not specified.
The verification of
• All results are checked by the company’s
significant intersections by Chief Technical Officer.
either independent or
• Field based geological logging for drill holes
alternative company
was entered directly into an Excel spreadsheet
personnel.
format with validation rules built into the
The use of twinned holes. spreadsheet including specific drop-down menus
Documentation of primary for each variable. This digital data was then
data, data entry
uploaded to the Australian Rare Earths Azure Data
procedures, data
Studio database.
verification, data storage • Assay data will be received in digital format
(physical and electronic)
from the laboratory and uploaded to Australian
protocols.
Rare Earths Azure Data Studio database.
Discuss any adjustment to • Field and laboratory duplicate data pairs of
assay data.
each batch will be plotted to identify potential
quality control issues.
• Standard Reference Material sample results
will be checked from each sample batch to ensure
they are within tolerance (<3SD) and that there is
no bias.
Accuracy and quality of
• All maps are in GDA94/MGA zone 54.
surveys used to locate drill • All overland coordinate information was
holes (collar and downcollected using handheld GPS utilizing
hole surveys), trenches,
GDA 1994, Zone 54. While spatial
mine workings and other
location is expected to be recovered
locations used in Mineral
within 3 – 5 m, it is possible that the
Resource estimation.
elevation can be as much as 10 m out
Specification of the grid
with respect to the currently established
system used.
geoid.
Quality and adequacy of
topographic control.
Data spacing for reporting • Locations of Overland drill holes are
of Exploration Results.
reported within the appendices of this
Whether the data spacing,
report.
and distribution is
•
Verification
of sampling
and assaying
Location of
data points
Data spacing
and
distribution
Orientation
of data in
relation to
geological
structure
Sample
security
sufficient to establish the
degree of geological and
grade continuity
appropriate for the
Mineral Resource and Ore
Reserve estimation
procedure(s) and
classifications applied.
Whether sample
compositing has been
applied.
Whether the orientation of
sampling achieves
unbiased sampling of
possible structures and the
extent to which this is
known, considering the
deposit type.
If the relationship between
the drilling orientation and
the orientation of key
mineralised structures is
considered to have
introduced a sampling
bias, this should be
assessed and reported if
material.
The measures taken to
ensure sample security.
•
•
•
No geological or grade continuity estimations
are being determined from the Overland
drilling data.
•
All Overland drill holes were drilled
vertically as detailed in the appendices of
this report.
•
There is no indication that a sampling
bias exists as the geology is relatively flat
lying therefore vertical holes are
appropriate.
After logging, the samples in calico bags
were tied and placed into polyweave bags,
labelled with the drill hole and sample
numbers contained within the polyweave
and transported to the site laydown area,
at the end of each day.
Sample selections were determined at the
drill site and at the end of the day the
polyweave bags were placed into bulk bags
for either sending to the lab or storage
facility.
•
Samples were shipped at a frequency of
once every 10 days during drilling
•
Samples were transported to the lab by AR3
personnel or by courier.
•
The laboratory inspected the packages and
did not report tampering of the samples
and provided a sample reconciliation report
for each sample dispatch.
Audits or
reviews
Criteria
Mineral
tenement
and land
tenure status
The results of any audits
or reviews of sampling
techniques and data.
•
Internal reviews were undertaken by AR3’s
Exploration Manager and Technical Director
during the drilling, sampling, an
Share your feedback