Drilling completed in 2024 reveals palaeovalley setting
Released
Released
Announcement PDF
21 January 2025
Overland Progress Update
Drilling completed in 2024 reveals “palaeovalley” setting, conducive host for
uranium mineralisation
Highlights:
•
3,271 meters drilled at Overland Project in 2024: 25 Air Core (AC) drill holes
completed including downhole gamma logging across the Overland Project area, a
new frontier uranium region in South Australia.
•
Palaeovalley defined: Drilling has defined a north/south trending palaeovalley
setting for the accumulation of thick sequences of Murray group stratigraphy
containing interbedded sands, clays and lignite horizons. This provides the ideal
host for the critical elements required for the formation of a sedimentary-hosted
uranium deposit.
•
Target Zone of lignite horizons and anomalous gamma identified:
o Drilling within the palaeovalley identified an abundance of lignite horizons
with associated anomalous downhole natural gamma readings along its
western margin.
o Significant potential for hosting uranium mineralization, with setting
providing substantial reductants and permeable sand sequences, providing
high priority follow up targets.
•
Geophysics review under way with CSIRO: This research project is part funded by
the CSIRO Kick-Start Program. Using historical geophysical (airborne
electromagnetic) data to map the sediment-basement architecture and
palaeochannel sequences with the Murray and Renmark Group sediments to assist
with drill targeting.
•
Next steps: Drilling to recommence later this month to map out the palaeovalley
within EL7001 and to follow up the high-priority target zone within its western margin.
•
Engage with this announcement at the AR3 investor hub.
AR3 Managing Director and CEO, Travis Beinke, said:
“Our inaugural drilling program at Overland, a new frontier uranium region in South Australia, has
provided us with confidence in our geological model for the potential of sedimentary-hosted
uranium deposits in the project area.
With the completion of the 2024 program we have demonstrated that the project area contains
the critical elements required for the formation of a sedimentary-hosted uranium deposit and we
are excited to have defined the presence of a palaeovalley within the first target area.
We have a significant position of ~4,000km2 in one of South Australia’s most prospective frontier
uranium regions and a substantial number of high-priority targets to test in time.
The 2025 drilling program will commence later this month. We will first map out the newly defined
palaeovalley further south within EL7001. Next, we will immediately follow up on the high-priority
target area along the western margin where an abundance of lignite horizons with associated
anomalous downhole natural gamma readings has been mapped.
With such a large, under-explored project area, the next phase of drilling will expand on our
understanding of the regional setting while also providing flexibility to follow up on high-priority
targets.
We anticipate an active tempo of AR3 progress updates as our uranium drilling program unfolds
in the first half of 2025.”
Australian Rare Earths Limited (ASX: AR3) is pleased to provide a progress update on drilling at
the Overland Uranium Project. The project area has been expanded to ~4,000km2, following the
recent Farm-In Agreement for the sedimentary-hosted uranium rights within EL6678 1 (Figure 1).
This region demonstrates strong potential for In-Situ Recovery (ISR) amenable, sedimentaryhosted uranium deposits. AR3 believes the paleochannel sediments of the Renmark Group and
Murray Group (Eyre and Namba equivalents) offer significant potential for uranium discovery.
Sedimentary Hosted Uranium Prospectivity supported by drilling completed in 2024
The conclusion of drilling in 2024, totalling 3,271 meters, has yielded compelling evidence
supporting AR3’s initial geological model. In particular it has defined the presence of a
north/south trending palaeovalley, providing the ideal host for the critical elements required for
the formation of a sedimentary-hosted uranium deposit, including:
•
•
•
connection to uranium rich source rocks,
permeable sediments as migration pathways and hosts, and
effective reductants acting as traps for uranium precipitation.
The drilling has continued to intersect thick sequences of the Murray group stratigraphy, within a
defined palaeovalley setting, containing sands, clays and on the western margin of the
palaeovalley, abundant lignite horizons, see Figure 3. This drilling has successfully identified all
the attributes required for pathways for uranium bearing groundwaters and for hosting uranium
mineralisation. Figures 4 and 5 illustrate examples of individual drillhole details from the western
margin. The drilling has also delineated primary targets within EL7001, which are now ready for
immediate drill testing (Figure 2).
This further validates AR3’s confidence in the Overland Project’s potential for significant uranium
mineralisation.
1
AR3 ASX release 19 November 2024
Figure 1: Overland project with approved work areas, regional geology.
AR3 is pursuing highly prospective drill targets along the western margin of a palaeovalley setting
within EL7001, defined through drilling completed in 2024 (Figure 2). Drilling will initially be
targeted to map the southern extension of the palaeovalley setting and then to test the primary
targets along its western margin. Drilling to date has identified this zone as highly prospective for
hosting uranium mineralisation.
Figure 2: -Overland drilling relative to airborne magnetics, faulting, and interpreted felsic intrusives. Recent drilling has defined
a highly prospective palaeovalley and western margin target zone- both targeted for immediate follow up drill testing.
Figure 3:Cross section A-A1 and B-B1 across the defined palaeovalley showing lithology, pXRF U (ppm), and Gamma (CPS).
Note the increased lignite horizons along the western margin and coinciding anomalous gamma response. Also note, the 2
Sections have been brought together in the same plane to illustrate the palaeovalley setting, see Figure 2 for section location
plan. In relation to the disclosure of pXRF results, the Company cautions that estimates of uranium elemental abundance
from pXRF results should not be considered a proxy for quantitative analysis of a laboratory assay result. Assay results are
required to determine the actual widths and grade of the mineralisation. The company uses an Olympus Vanta M Series portable
X-ray Fluorescence (pXRF) analyzer to screen Air Core drilling samples for mineralization prior to submitting samples to a
commercial laboratory for assay. This provides an initial understanding of the mineralization distribution before sampling,
ensuring submitted samples are representative of the targeted mineralization. While pXRF confirms the presence of
mineralization, it does not accurately determine elemental concentrations due to limitations such as a small analysis window,
uneven distribution, shallow penetration depth, and irregular surfaces. The pXRF results are indicative and the pXRF readings
are subject to confirmation by chemical analysis from an independent laboratory.
Figure 4: Examples of down hole logging detail, with anomalous natural gamma readings (CPS) and pXRF U (ppm) including
some of the highest peak gamma responses of 406 CPS in hole OV011 at ~95m, 350 CPS in hole OV012 at ~92m, and peak
pXRF U ppm responses of 39 ppm in hole OV011 from 90-91m and 45 ppm in hole OV012 from 103-104m. In relation to the
disclosure of pXRF results, the Company cautions that estimates of uranium elemental abundance from pXRF results
should not be considered a proxy for quantitative analysis of a laboratory assay result. Assay results are required to
determine the actual widths and grade of the mineralisation. The company uses an Olympus Vanta M Series portable X-ray
Fluorescence (pXRF) analyzer to screen Air Core drilling samples for mineralization prior to submitting samples to a
commercial laboratory for assay. This provides an initial understanding of the mineralization distribution before sampling,
ensuring submitted samples are representative of the targeted mineralization. While pXRF confirms the presence of
mineralization, it does not accurately determine elemental concentrations due to limitations such as a small analysis
window, uneven distribution, shallow penetration depth, and irregular surfaces. The pXRF results are indicative and the pXRF
readings are subject to confirmation by chemical analysis from an independent laboratory.
Figure 5: Examples of down hole logging detail, with anomalous natural gamma readings (CPS) and pXRF U (ppm) including
some of the highest peak gamma responses of 360 CPS in hole OV013 at ~88m, 385 CPS in hole OV014 at ~91m, and peak
pXRF U ppm responses of 57 ppm in hole OV013 from 85-86m and 25 ppm in hole OV014 from 93-94m. In relation to the
disclosure of pXRF results, the Company cautions that estimates of uranium elemental abundance from pXRF results
should not be considered a proxy for quantitative analysis of a laboratory assay result. Assay results are required to
determine the actual widths and grade of the mineralisation. The company uses an Olympus Vanta M Series portable X-ray
Fluorescence (pXRF) analyzer to screen Air Core drilling samples for mineralization prior to submitting samples to a
commercial laboratory for assay. This provides an initial understanding of the mineralization distribution before sampling,
ensuring submitted samples are representative of the targeted mineralization. While pXRF confirms the presence of
mineralization, it does not accurately determine elemental concentrations due to limitations such as a small analysis
window, uneven distribution, shallow penetration depth, and irregular surfaces. The pXRF results are indicative and the pXRF
readings are subject to confirmation by chemical analysis from an independent laboratory.
Next steps
Drilling is set to continue in the northwest of EL7001 targeting the palaeovalley setting defined
there and its western margin (Figure 2). Drilling will target thick sequences of interbedded sands,
clays and lignite horizons within the Murray Group sediment along the western margin of the
palaeovalley, as this area is considered highly prospective for hosting uranium mineralisation.
A drilling contractor has been engaged for this work and is planned to commence this month.
Work currently underway by CSIRO Minerals, to map the sediment-basement architecture, and
palaeochannel sequences within the Murray and Renmark Group sediments using historical
geophysical (airborne electromagnetic) data across AR3 tenure, will be concluded and assessed
for its future application in assisting drill targeting. This research project will be part funded by
the CSIRO Kick-Start Program. Kick-Start is an initiative for innovative Australian start-ups and
SMEs, providing funding support and access to CSIRO’s research expertise and capabilities to
help grow and develop their business.
The announcement has been authorised for release by the Board of Australian Rare Earths Limited.
For further information please contact:
Australian Rare Earths Limited
Travis Beinke
Managing Director and CEO
T: 1 300 646 100
Media Enquiries
Jessica Fertig
Tau Media
E: info@taumedia.com.au
Engage and Contribute at the AR3 investor hub: https://investorhub.ar3.com.au/
Competent Person’s Statement
The information in this report that relates to Exploration results is based on information compiled by Australian
Rare Earths Limited and reviewed by Mr Rick Pobjoy who is the Chief Technical Officer of the Company and a
member of the Australian Institute of Mining and Metallurgy (AusIMM). Mr Pobjoy has sufficient experience that
is relevant to the style of mineralisation, the type of deposit under consideration and to the activities undertaken
to qualify as a Competent person as defined in the 2012 edition of the “Australasian Code for Reporting of
Exploration Results, Mineral Resources and Ore Reserves”. Mr Pobjoy consents to the inclusion in this report of
the matters based on this information in the form and context in which it appears.
About Australian Rare Earths Limited
Australian Rare Earths is committed to the timely exploration and development of its 100% owned, flagship
Koppamurra Project, located in the new Koppamurra rare earths Province in southeastern South Australia and
western Victoria. Koppamurra is a prospective ionic clay hosted rare earth deposit, rich in all the elements
required in the manufacture of rare earth permanent magnets which are essential components in electric
vehicles, wind turbines and domestic appliances. In addition, AR3 is actively reviewing other potential
prospective areas which may also host uranium and ionic clay hosted rare earth deposits throughout Australia.
The Company is focused on executing a growth strategy that aims to position AR3 as an independent and
sustainable source of energy transition metals, playing a pivotal role in the global transition to a green economy.
JORC Table 1
Criteria
Sampling
techniques
Section 1 Sampling Techniques and Data
Explanation
Comment
Nature and quality of
Air Core drilling methods were used to obtain
sampling (e.g., cut
samples from the Overland drilling program.
channels, random chips, or
specific specialised
The following information details the Air Core drill
industry standard
sampling process:
measurement tools
All Air Core drill samples were collected from
appropriate to the
the rotary splitter mounted at the bottom of
minerals under
the cyclone into a pre‐numbered calico bag.
investigation, such as
The samples were geologically logged at 1 m
down hole gamma sondes,
intervals.
or handheld XRF
Based on hole‐diameter, generic material
instruments, etc). These
density and a 20% split on the cyclone
examples should not be
samples averaged ~1.5‐2.5 kg in mass.
taken as limiting the broad
meaning of sampling.
Chip trays were used to collect a
Include reference to
representative sample for each 1m sample
measures taken to
interval for each hole.
ensure sample
After the samples were collected within the
representivity and the
calico bags, they were screened for
appropriate calibration
anomalous gamma radiation using a
of any measurement
handheld Ranger EXP survey meter (S/N
tools or systems used.
R318772) calibrated 23/09/2024 prior to
Aspects of the
being geologically logged and tested with a
determination of
pXRF
at the drill site.
mineralisation that are
Material to the Public
The gamma screening was conducted by
Report. In cases where
placing the handheld Ranger survey meter
‘industry standard’ work
~10cm from the calico sample for 5‐10sec
has been done this would
and noting the dose rate in µSv. If elevated
be relatively simple (e.g.,
dose rates were detected the field crew was
‘reverse circulation drilling
then notified before any additional sample
was used to obtain 1 m
logging was conducted and the anomalous
samples from which 3 kg
reading recorded in the geological log.
was pulverised to produce
A handheld Olympus Vanta pXFR Analyser
a 30 g charge for fire
(Model Vanta M Series S/N 842924) was
assay’). In other cases,
used
to assess the geochemistry of the Air
more explanation may be
Core samples in the field. The pXRF analysis
required, such as where
provided
screening analysis to characterize
there is coarse gold that
the sample lithology and full suite.
has inherent sampling
problems. Unusual
The pXRF sampling was analized through
commodities or
the calico bag with a beam count time of 30
mineralisation types (e.g.,
sec beam 1 and 10 sec beam 2. One analysis
submarine nodules) may
warrant disclosure
of detailed information.
per sample was performed.
Samples are laid on a workbench and
flattened to create a stable surface for the
pXRF. The pXRF is placed on the sample with
the beam down for the analysis.
All readings were taken at ambient
temperatures between 20 and 40 degrees
Celsius. The Olympus Vanta is rated for
continuous
operation
within
these
temperatures.
Samples range from dry to wet, this is
dependent on which formation is being
intercepted and whether drilling water has
been injected.
A Uranium standard Oreas 121 (215 ppm U,
sourced from Mantra Resources Nyota
Prospect, Tanzania, which is a Tabular
Sandstone hosted deposit) was used to
verify the accuracy of the pXRF before and
after each analysis session.
The OREAS 121 standard was prepared
using an industry standard pXRF sample cup
and analized for 30 sec on beam 1 and 10
Sec on beam 2.
A silica blank is used to monitor the
accumulation of contamination on the lens
of the pXRF. Analysis of the blank is
undertaken before and after each analysis
session.
Review of pXRF standard and blank data is
checked to ensure the pXRF is operating
correctly before and after each session.
Samples were selected for assay at the end of
the hole based on geology, pXRF, and
natural downhole gamma response.
Field duplicates were taken at a rate of ~1:40
and inserted blindly into the sample batches.
Field Standards were taken at a rate of ~1:40
and inserted blindly into the samples batches.
Samples were submitted to Bureau Veritas in
Adelaide for analysis. The sample weights
were recorded (wet and dry) and samples
were oven dried at 105 degrees for a
minimum of 24 hours. The samples were
secondary crushed to 3 mm fraction and
then pulverised to 90% passing 75 µm.
Excess residue was maintained for storage
while the rest of the sample placed in 8x4
packets and sent to the central weighing
laboratory. The samples were submitted for
analysis using Mixed Acid Digest – Lithium
Borate Fusion ICP‐MS method (BV Code
SC302) for Ag (0.1), Al (100), As (1), Ba (1), Be
(0.5), Bi (0.1), Ca (100), Cd (0.5), Ce (0.1), Co
(1), Cr (10), Cs (0.1), Cu (1), Dy (0.05), Er
(0.05), Eu (0.05), Fe (100), Ga (0.2), Gd (0.2),
Hf (0.2), Ho (0.02), In (0.05), K (100), La (0.5),
Li (0.5), Lu (0.02), Mg (100), Mn (2), Mo (0.5),
Na (100), Nb (0.5), Nd (0.05), Ni (2), P (100),
Pb (1), Pr (0.2), Rb (0.2), Re (0.1), S (50), Sb
(0.1), Sc (1), Se (5), Si (100), Sm (0.05), Sn (1),
Sr (0.5), Ta (0.1), Tb (0.02), Te (0.2), Th (0.1),
Ti (50), Tl (0.1), Tm (0.2), U (0.1), V (5), W
(0.5), Y (0.1), Zn (2), Zr (1), Yb (0.05)
Select samples were also analyzed for gold
using Lead collection Fire Assay AAS (BV Code
FA001)
A laboratory repeat was taken at ~ 1 in 21
samples;
Commercially obtained standards were
inserted by the laboratory at a rate of ~ 1 in
9 into the sample sequence.
After the hole was drilled to completion a
Reflex EZ Gamma logging tool (serial number
GAM‐043) rented from Imdex, and operated
by the drilling crew was run down the hole,
inside the rods/innertube to log the natural
gamma response of the sediments. The
gamma tool was last calibrated by Imdex on
October 9th 2024 as noted in the provided
Certificate of Conformance.
The survey was run in and out of the hole at a
speed of no more than 10m/min and the
downhole speed was reviewed after the
survey.
The up (out) survey was then used to plot on
sections, after reviewing both in and out
gamma surveys.
Before each downhole gamma survey the
Reflex EZ Gamma logging tool was checked
with a EZ‐Gamma confidence checker by AR3
staff (S/N 025). The confidence checker was
last calibrated 29/08/24.
Using the EZ‐Gamma confidence checker at
the start of each run allows the gamma tool
to be checked ensuring it is within
specifications and the tool has not been
damaged or faulty providing confidence an
accurate gamma reading is collected for each
hole.
The check is completed by first running the
gamma tool for 5min to measure background
gamma, then a second survey after sliding
the EZ‐Gamma Confidence checker over the
gamma probe and subtracting the
background. The resulting pass value of ~600
cps +/‐ 5% is required before the survey tool
is confirmed as operating within expected
limits.
After the gamma survey is completed the
data is uploaded to the Imdex hub IQ portal
(https://iq.imdexhub.com) from the rig via
satellite internet and available for review.
The Fairview uranium occurrence shown on
maps within this report is based on reported
SA Geodatabase Reference sample #152296
(Explorers sample 45835) sourced from the
SA Geodatabase available on SARIG
https://minerals.sarig.sa.gov.au/RockSamp
leDetails.aspx?SampleNo=45835
Sample #152296 was collected by A.F. Crooks
on 20/08/1984 and the sample was
analyzed by XRF. Details on the lab or XRF
device were not specified.
Drilling
techniques
Drill type (e.g., core,
reverse circulation, open‐
hole hammer, rotary air
blast, auger, Bangka,
sonic, etc) and details
(e.g., core diameter, triple
or standard tube, depth of
diamond tails, face‐
Drilling was completed using a Wallis
“Mantis 200”Air Core drill rig with an
onboard Sullair compressor (560cfm @
200psi).
Aircore drilling is a form of reverse
circulation drilling where the sample is
sampling bit, or other
type, whether core is
oriented and if so, by what
method, etc).
Drill sample
recovery
Logging
Method of recording and
assessing core and chip
sample recoveries and
results assessed.
Measures taken to
maximise sample recovery
and ensure representative
nature of the samples.
Whether a relationship
exists between sample
recovery and grade and
whether sample bias may
have occurred due to
preferential loss/gain of
fine/coarse material.
collected at the face and returned inside the
inner tube. The drill cuttings are removed by
injection of compressed air into the hole via
the annular area between the inner tube and
the drill rod.
Aircore drill rods used were 3 m long.
NQ diameter (76 mm) drill bits and rods were
used.
All aircore drill holes were vertical with
depths varying between ~140 m and 200 m.
Drill sample recovery for Air Core drilling is
monitored by recording sample condition
descriptions where ‘Poor’ to ‘Very Poor’ were
used to identify any samples recovered
which were potentially not representative of
the interval drilled.
A comment was included where water
injection was required to recover the sample
from a particular interval. The use of water
injection can potentially bias a sample.
Minimal water injection was required during
this drilling program and used sparingly.
No significant loses of sample material was
observed.
The rotary splitter was set to an approximate
20% split, which produced approximately
1.5‐2.5 kg sample for each meter interval.
The 1.5‐2.5 kg sample was collected in a pre‐
numbered calico bag and the remaining 80%
(5 kg to 8 kg) was disposed directly into the
sump as drilling progressed.
At the end of each drill rod, the drill string is
cleaned by blowing down with air to remove
any clay and silt potentially built up in the
sample pipes and cyclone.
The relationship (if any) between sample
recovery and grade is unknown
No sample recovery information was
reported in historical reports relating to
historical drilling within this release.
Whether core and chip
All Air Core samples collected in calico bags
samples have been
were logged for lithology, colour, cement
geologically and
type, hardness, percentage rock es mate,
geotechnically logged to a
sor ng, and any relevant comments such as
level of detail to support
moisture, sample condi on, evidence of
appropriate Mineral
Resource estimation,
mining studies and
metallurgical studies.
Whether logging is
qualitative or quantitative
in nature. Core (or
costean, channel, etc)
photography.
The total length and
percentage of the relevant
intersections logged.
Sub‐sampling
techniques
and sample
preparation
If core, whether cut or
sawn and whether
quarter, half or all cores
taken.
If non‐core, whether
riffled, tube sampled,
rotary split, etc and
whether sampled wet or
dry.
For all sample types, the
nature, quality, and
appropriateness of the
sample preparation
technique.
Quality control
procedures adopted for
all sub‐sampling stages to
maximise representivity
of samples.
Measures taken to ensure
that the sampling is
representative of the in‐
situ material collected,
including for instance
results for field
duplicate/second‐half
sampling.
reducing or oxidizing condi ons, and
vegeta on/organic material.
Geological logging data for all drill holes was
qualita vely logged onto Microso Excel
spreadsheet using a field laptop with
valida on rules built into the spreadsheet
including specific drop‐ down menus for each
variable. The data was uploaded to the
Australian Rare Earths Azure Data Studio
database.
Every drill hole was logged in full and logging
was undertaken with reference to a drilling
template with codes prescribed and guidance
to ensure consistent and systema c data
collec on.
The detail of logging is not sufficient to
support considera on of resource es ma on,
mining, or metallurgical studies and no
geotechnical logging was completed.
1m Air Core sample interval was
homogenised within the cyclone and the
rotary splitter was set to an approximate
20% split producing around 1.5‐2.5 kg
sample for each metre interval.
The 1.5‐2.5kg sample was collected in a
pre‐numbered calico bag and the 80% (5 kg
to 8 kg) portion was disposed directly into
the sump as drilling progressed.
Duplicates were generally taken within
intervals which indicated potential for
anomalous U mineralization based on
geology, pXRF, and gamma signature. These
duplicate samples were collected by splitting
the 1m interval by emptying the sample on
to a table, mixing and splitting into 1/8th
subsamples and randomly assigning 4 of the
splits into the duplicate and 4 remaining as
the primary.
The 1.5‐2.5 kg sample collected in the calico
bag was logged by the geologist onsite.
Approximately 10‐20g of sample material
from each for each 1m calico sample placed
in a chip tray.
The logged calico samples were scanned
with a pXRF onsite through the calico bag.
At the end of the drillhole samples were
Whether sample sizes are
appropriate to the grain
size of the material being
sampled.
selected for analysis.
Samples were placed in polyweave bags
labelled with the sample number, From‐To
interval, and Hole ID, then segregated into
bulka bags for transport either to the lab for
analysis or to AR3’s warehouse or similar
storage facility.
No correction factors were applied to pXRF
results.
Field duplicates of all the samples were
Quality of
assay data
and
laboratory
tests
completed at a frequency of ~1 in 40
samples. Field standards were inserted into
the sample sequence at a frequency of
~1:40. Standard reference Material (SRM)
samples were inserted into the sample
batches at a frequency rate of 1 per 10
samples by the laboratory and a repeat
sample was taken at a rate of 1 per 21
samples.
An on‐site geologist oversaw the sampling
and logging process and selected samples for
analysis based on the logging descrip ons
Pxrf analysis, and downhole gamma
response.
•The detailed geological logging of samples
provides lithology (sand/clay component)
The nature, quality and
appropriateness of the
assaying and laboratory
•The 1.5 kg air core samples were assayed by
procedures used and
Bureau Veritas laboratory in Wingfield, Adelaide,
whether the technique is
South Australia, which is considered the Primary
considered partial or total.
laboratory.
For geophysical tools,
spectrometers, handheld •The samples will be ini ally oven dried at 105
XRF instruments, etc, the degrees Celsius for 24 hours. Samples will be
parameters used in
secondary crushed to 3 mm frac on and the
determining the analysis
weight recorded. The sample will then be
including instrument make pulverised to 90% passing 75 µm. Excess residue
and model, reading times, will be maintained for storage while the rest of
calibrations factors
the sample is placed in 8x4 packets and sent to
applied and their
the central weighing laboratory.
derivation, etc.
Nature of quality control •All weighed samples will then be analysed using
procedures adopted (e.g., the Mul ple Elements Fusion/Mixed Acid Digest
analy cal method;
standards, blanks,
duplicates, external
•ICP Scan (Mixed Acid Digest – Lithium Borate
laboratory checks) and
Fusion) Samples are digested using a mixed acid
whether acceptable levels digest and also fused with Lithium Borate to
of accuracy (i.e., lack of
ensure all elements are brought into solu on. The
bias) and precision have
been established.
digests are then analysed for the following
elements (detec on Limits shown): Al (100) As (1)
Ba (1) Be (0.5) Ca(100) Ce (0.1) Co (1) Cr (10) Dy
(0.05) Er (0.05) Eu(0.05) Fe(100) Gd (0.2) Ho
(0.02) K (100) La (0.5) Lu (0.02) Mg (100) Mn (2)
Na (100) Nd (0.05) Ni (2) Pr (0.2) S (50) Sc (1) Si
(100) Sm(0.05) Sr (0.5) Th (0.1) Ti (50) Tm (0.2) U
(0.1) V (5) Y (0.1) Yb (0.05) Zr (1)
Select samples that were deemed likely to be
of basement lithology (or saprolite) were also
analyzed for Au Fire Assay with a detection
limit of (0.01)
•Field duplicates were collected and submi ed at
a frequency of ~1 per 40 samples.
• Bureau Veritas will complete its own internal
QA/QC checks that include a Laboratory repeat
every 21st sample and a standard reference
sample every 9th sample prior to the results
being released.;
• Australian Rare Earths submi ed field
standards at a frequency of ~1:40 samples.
• Australian Rare Earths requested BV insert
blank washes at a frequency of 1:40 samples.
These blank washes were inserted in the sample
sequence behind samples which were thought to
be mineralized to ensure that no contamina on
from higher grade samples was occurring.
Frequency of blank samples totalled ~1 in 40
samples.
The adopted QA/QC protocols are acceptable for
this stage of test work. The sample prepara on
and assay techniques used are industry standard
and provide a total analysis.
Historical data referenced within this report is
detailed below;
The Fairview uraniu